AudioCodes Mediant 500L User Manual page 681

Enterprise session border controller (e-sbc) & media gateway
Hide thumbs Also See for Mediant 500L:
Table of Contents

Advertisement

User's Manual
2.
Click New; the following dialog box appears:
3.
Configure the Classification rule according to the parameters described in the table
below.
4.
Click Apply.
Table 35-1: Classification Table Parameter Descriptions
Parameter
SRD
srd-name
[Classification_SRDName]
Match
Index
[Classification_Index]
Name
classification-name
[Classification_Classification
Name]
Source SIP Interface
src-sip-interface-name
[Classification_SrcSIPInterfa
ceName]
Version 7.2
Figure 35-3: Classification Table - Add Dialog Box
Assigns an SRD to the rule as a matching characteristic for the
incoming SIP dialog.
If only one SRD is configured in the SRDs table, the SRD is assigned
to the rule by default. If multiple SRDs are configured in the SRDs
table, no value is assigned.
To configure SRDs, see ''Configuring SRDs'' on page 345.
Note: The parameter is mandatory.
Defines an index number for the new table row.
Note: Each row must be configured with a unique index.
Defines a descriptive name, which is used when associating the row in
other tables.
The valid value is a string of up to 40 characters. By default, no name
is defined.
Note: Each row must be configured with a unique name.
Assigns a SIP Interface to the rule as a matching characteristic for the
incoming SIP dialog.
The default is Any (i.e., all SIP Interfaces belonging to the SRD
assigned to the rule).
Note: The SIP Interface must belong to the SRD assigned to the rule
Description