AudioCodes Mediant 500L User Manual page 955

Enterprise session border controller (e-sbc) & media gateway
Hide thumbs Also See for Mediant 500L:
Table of Contents

Advertisement

User's Manual
Parameter
Filter Type
filter-type
[LoggingFilters_FilterType]
Value
value
[LoggingFilters_Value]
Version 7.2
Defines the filter type criteria.
[1] Any (default)
[2] Trunk ID = Filters log by Trunk ID. Note: Applicable only to
the Gateway application.
[3] Trunk Group ID = Filters log by Trunk Group ID. To configure
Trunk Groups, see Configuring Trunk Groups on page 501.
Note: Applicable only to the Gateway application.
[4] Trunk & B-channel = Filters log by Trunk and B-channel.
Note: Applicable only to the Gateway application.
[5] FXS or FXO = Filters log by FXS and/or FXO port.
[6] Tel-to-IP = Filters log by Tel-to-IP routing rule. To configure
Tel-to-IP routing rules, see Configuring Tel-to-IP Routing Rules
on page 509. Note: Applicable only to the Gateway application.
[7] IP-to-Tel = Filters log by IP-to-Tel routing rule. To configure
IP-to-Tel routing rules, see Configuring IP-to-Tel Routing Rules
on page 518. Note: Applicable only to the Gateway application.
[8] IP Group = Filters log by IP Group. To configure IP Groups,
see ''Configuring IP Groups'' on page 363.
[9] SRD = Filters log by SRD. To configure SRDs, see
Configuring SRDs on page 345.
[10] Classification = Filters log by Classification rule. To
configure Classification rules, see Configuring Classification
Rules on page 677. Note: Applicable only to the SBC
application.
[11] IP-to-IP Routing = Filters log by IP-to-IP routing rule. To
configure IP-to-IP routing rules, see Configuring SBC IP-to-IP
Routing Rules on page 685. Note: Applicable only to the SBC
application.
[12] User = Filters log by user. The user is defined by username
or username@hostname in the Request-URI of the SIP
Request-Line. For example, "2222@10.33.45.201", which
represents the following INVITE:
INVITE sip:2222@10.33.45.201;user=phone
SIP/2.0
[13] IP Trace = Filters log by an IP network trace, Wireshark-like
expression. For more information, see ''Filtering IP Network
Traces'' on page 958.
[14] SIP Interface = Filters log by SIP Interface. To configure SIP
Interfaces, see Configuring SIP Interfaces on page 355.
Defines the value for the filtering type configured in the 'Filter Type'
parameter.
The value can include the following:
A single value.
A range, using a hyphen "-" between the two values. For
example, to specify IP Groups 1, 2 and 3, configure the
parameter to "1-3" (without apostrophes).
Multiple, non-contiguous values, using commas "," between
each value. For example, to specify IP Groups 1, 3 and 9,
configure the parameter to "1,3,9" (without apostrophes).
Trunks/FXO/FXS pertaining to a module, using the syntax
module number/port or port, for example:
955
60. Syslog and Debug Recording
Description
Mediant 500L Gateway & E-SBC

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents