Parameter
Call Waiting Table
Call Waiting
configure voip > gateway analog
call-waiting
[CallWaitingPerPort]
Number of Call Waiting
Indications
configure voip > gateway dtmf-
supp-service supp-service-
settings > nb-of-cw-ind
[NumberOfWaitingIndications]
Time Between Call Waiting
Indications
configure voip > gateway dtmf-
supp-service supp-service-
settings > time-between-cw
[TimeBetweenWaitingIndications]
Time Before Waiting Indications
configure voip > gateway dtmf-
supp-service supp-service-
settings > time-b4-cw-ind
[TimeBeforeWaitingIndications]
Waiting Beep Duration
configure voip > gateway dtmf-
supp-service supp-service-
settings > waiting-beep-dur
[WaitingBeepDuration]
Version 7.2
The device's Call Progress Tones (CPT) file must include a
Call Waiting ringback tone (caller side) and a call waiting tone
(called side, FXS only).
FXS interfaces: The EnableHold parameter must be enabled
on both the calling and the called side.
Analog interfaces: You can use the table parameter
CallWaitingPerPort to enable Call Waiting per port.
Analog interfaces: For information on the Call Waiting feature,
see Enabling Call Waiting on page 581.
Defines call waiting per FXS port.
The format of the ini file table parameter is as follows:
[CallWaitingPerPort]
FORMAT CallWaitingPerPort_Index =
CallWaitingPerPort_IsEnabled, CallWaitingPerPort_Module,
CallWaitingPerPort_Port;
[\CallWaitingPerPort]
For example:
CallWaitingPerPort 0 = 0,1,1; (call waiting disabled for Port 1 of
Module 1)
CallWaitingPerPort 1 = 1,1,2; (call waiting enabled for Port 2 of
Module 1)
Note:
The parameter is applicable only to FXS ports.
For more information, see Configuring Call Waiting on page
621.
Defines the number of call waiting indications that are played to
the called telephone that is connected to the device for Call
Waiting.
The valid range is 1 to 100 indications. The default is 2.
Note: The parameter is applicable only to FXS ports.
Defines the time (in seconds) between consecutive call waiting
indications for call waiting.
The valid range is 1 to 100. The default is 10.
Note: The parameter is applicable only to FXS ports.
Defines the interval (in seconds) before a call waiting indication is
played to the port that is currently in a call.
The valid range is 0 to 100. The default time is 0 seconds.
Note: The parameter is applicable only to FXS ports.
Defines the duration (in msec) of call waiting indications that are
played to the port that is receiving the call.
The valid range is 100 to 65535. The default is 300.