Parameter
Version 7.2
(default).
Note: This option is applicable only to ISDN variants where
a complete ASN1 decoding is performed on Facility IE.
[128] SEND USER CONNECT ACK = The Connect ACK
message is sent in response to received Q.931 Connect;
otherwise, the Connect ACK is not sent.
Note: This option is applicable only to Euro ISDN User side
outgoing calls.
[2048] ALWAYS EXPLICIT = Always set the Channel
Identification IE to explicit Interface ID, even if the B-
channel is on the same trunk as the D-channel.
Note: This value is applicable only to 4/5ESS, DMS and NI-
2 variants.
[32768] ACCEPT MU LAW =Mu-Law is also accepted in
ETSI.
[65536] EXPLICIT PRES SCREENING = The calling party
number (octet 3a) is always present even when
presentation and screening are at their default.
Note: This option is applicable only to ETSI, NI-2, and
5ESS.
[131072] STATUS INCOMPATIBLE STATE = Clears the
call on receipt of Q.931 Status with incompatible state.
Otherwise, no action is taken (default).
[262144] STATUS ERROR CAUSE = Clear call on receipt
of Status according to cause value.
[524288] ACCEPT A LAW =A-Law is also accepted in
5ESS.
[2097152] RESTART INDICATION = Upon receipt of a
Restart message, acEV_PSTN_RESTART_CONFIRM is
generated.
[4194304] FORCED RESTART = On data link
(re)initialization, send RESTART if there is no call.
[67108864] NS ACCEPT ANY CAUSE = Accept any Q.850
Cause IE from ISDN.
Note: This option is applicable only to Euro ISDN.
[134217728] NS_BRI_DL_ALWAYS_UP (0x08000000) =
By default, the BRI D-channel goes down if there are no
active calls. If this option is configured, the BRI D-channel is
always up and synchronized.
[536870912] = Alcatel coding for redirect number and
display name is accepted by the device.
Note: This option is applicable only to QSIG (and relevant
for specific Alcatel PBXs such as OXE).
[1073741824] QSI ENCODE INTEGER = If this bit is set,
INTEGER ASN.1 type is used in operator coding (compliant
to new ECMA standards); otherwise, OBJECT IDENTIFIER
ASN.1 type is used.
Note: This option is applicable only to QSIG.
[2147483648] 5ESS National Mode For Bch Maintenance =
Use the National mode of AT&T 5ESS for B-channel
maintenance.
Note: