5. 1 , 5.2 Power Supply 1-2 Alarm

These parameters control how the FS-HDR alarm responds to a power supply
disconnection or failure. If the FS-HDR will be connected using only one power
cord, you can suppress the alarm, which only changes the color of the front panel
LED for the disconnected power supply.
Normal (default)
Suppress

6 Vid Format Alarm

(Single Ch only) When set to Normal (default), an alarm is triggered (the Channel
Select LED of that video processor [VID1 - Vid4] will light red) whenever the
selected input video signal format for that Video Processor is incompatible with
the selected output format. You can suppress the Format Alarm if you wish.
Normal (default)
Suppress

6. 1 -6.4 Vid1-4 Format Alarm

(4Ch only) Same as Vid 1 Format Alarm menu, except for Video Processors 1-4.

7 Reference Alarm

This parameter controls how the FS-HDR responds when the Video Processors
has a format that is incompatible with the Reference video signal. When set to
NORMAL, the alarm triggers (the REF LED on the FS-HDR front panel will light
red) if the Reference signal is not detected or is incompatible with the processor
format. You can suppress the Reference alarm is you wish.
Normal (default)
Suppress
NOTE: For proper operation the Input reference signal must be stable and properly

8 Hidden Menus

This parameter lets you choose whether to hide or show inactive menus.
Hide Inactive (default)
Show All

9 Screen Saver

This parameter lets you choose the menu screen saver.
On (AJA Logo) (default)
Off
System Name
FS-HDR Frame Synchronizer/Converter/HDR-WCG Processor v1.0r1
Alarm triggers if either internal power supply experiences a failure or
is disconnected from mains power.
Alarm will not be triggered by a power supply failure or disconnection
from power.
Alarm triggers if the format of the selected input video signal is
incompatible with the selected output format.
Alarm will not be triggered by a format incompatibility.
Alarm triggers if the reference signal is not detected or is
incompatible with the processor format.
Alarm will not be triggered by reference errors.
terminated using a 75-ohm terminator on either the unused loop connector or
the last piece of downstream equipment to which the Ref Video is connected.
Hides menus that are not in use.
Shows all menus, even those that are not in use.
AJA logo screen saver is displayed
The screen saver is not displayed.
Screen saver displays the system name.