Promise Technology Network Device EX4650 User Manual page 212

Promise technology network device user manual
Table of Contents

Advertisement

SuperTrak EX Series User Manual
mod
locate
-e <encl id>
-s "<option>=<value>" Specifies the settings to change.
tempwarning=
10..51
tempcritical=
52..61
ctrltempwarning= Controller warning theshold temperature, in degrees
10..61
ctrltempcritical=
62..71
-t <FRU type>
ctrl
cooling
psu
-f <FRU id>
-v
Examples
enclosure
enclosure -v
enclosure -a mod -s "tempwarning=40,tempcritical=55"
event
Usage
event [-a <action>] [-l <location>] [-i <SeqNo>] [-c <event count>] [-v]
Modifies settings. Requires the -s option.
Locates an enclosure by flashing its LEDs.
Enclosure ID. The default value is 1 if unspecified.
For list action, the default is for all enclosures if
unspecified.
Enclosure warning theshold temperature, in degrees
Celsius.
Enclosure critical theshold temperature, in degrees
Celsius.
Celsius.
Controller critical threshold temperature, in degrees
Celsius.
Specifies which type of FRU to locate. Requires -a locate
option.
Locates the controller.
Locates the cooling unit. Only works with SAS type
enclosure.
Locates the power supply unit. Only works with SAS type
enclosure.
Specifies id of FRU to locate. Requires -a locate option.
Valid values are 1 and 2.
Verbose mode. Requires -a list option. VPD information
is displayed.
198