To add a MEP, click on the Add MEP button next to a configured MA at the bottom of the CFM Settings window. The
following window opens:
Click
View Detail
to display MEP Information.
The fields that can be configured are described below:
Parameter
MEP Name
MEP ID
Port
MEP Direction
NOTE: The MEP Name value should be less than 32 characters.
Click Add to implement changes made. To view detailed information about the MEP entry, click on the View Detail
link.
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet User Manual
Figure 10- 3 CFM MIP Table window
Figure 10- 4 CFM MEP Settings window
Description
MEP name. It is unique among all MEPs configured on the device.
MEP MEPID. It should be configured in the MA's MEP ID list.
Port number. This port should be a member of the MA's associated VLAN.
This is the MEP direction.
Inward - Inward facing (up) MEP. An Inward facing MEP drops all CFM frames at its level or
lower that are received from the Inward side; and forwards all CFM frames at a higher level
regardless of the origin of the frame, Inward or Outward.
Outward - Outward facing (down) MEP. An Outward facing port drops all CFM frames at it
level or lower coming from the bridge relay function side. It processes all CFM frames at its
level, and drops all CFM frames at a lower level, coming from the bridge port. An Outward
facing port forwards all CFM frames at higher levels regardless of which direction the frames
come in.
271