4
ADVANCED OPERATION
Emergency call
IMPORTANT: It is recommended that the dealer sets
an Emergency channel in each Zone, to provide a
reliable Emergency call operation�
NOTE: Depending on the presetting, the following
functions may be automatically activated�
Auto TX function
After an Emergency call transmission, the
transceiver transmits the microphone audio for a
preset period of time�
Auto RX function
After an Emergency call transmission, the
transceiver stands by in the Audible mode for a
preset period of time�
TIP: A user can transmit the Emergency call in
the 2-Tone, 5-Tone, NXDN™, MDC 1200, or BIIS
signaling system�
D Transmitting an Emergency call
When the transceiver enters the Emergency mode, a
countdown starts� The transceiver counts down during
the Reminder Timer set time�
Before the Reminder Timer set time expires, the
transceiver transmits an Emergency call once, or
repeatedly*,onthespecifi edEmergencychannel.
IfnoEmergencychannelisspecifi ed,theEmergency
call is made on the previously selected channel�
* Depending on the presetting�
L The transceiver automatically transmits a
repeat Emergency call until it receives an
acknowledgement, or until a user turns OFF the
transceiver�
L If the transceiver is set for Silent operation, it
transmits an Emergency call without a beep
sounding or the status indicator lighting�
The transceiver enters the Emergency mode through
the following functions:
• The [Emergency] key
When a user holds down [Emergency] for the Emer
SW ON Timer preset time�
L If a user holds down [Emergency] for the Emer SW
OFF Timer set time before the Reminder Timer
expires, the Emergency mode is canceled�
Enters the
Emergency mode.
ON Timer
[Emergency]
4-3
Sends an
Emergency call.
Reminder Timer
Emergency Timer
[Emergency]
Time
If holding down [Emergency]
during the Reminder Timer,
the Emergency mode is
canceled.