6
MENU SCREEN
Vibration
OP Vibration
Selects whether or not to vibrate the transceiver when
it is turned ON�
L To use this function, the Vibration function must be
turned ON, in advance�
• OFF:
Turns OFF the vibration�
• Pattern 01:
The transceiver vibrates for 5
seconds�
• Pattern 02:
The transceiver vibrates for 1
second three times�
• Pattern 03:
The transceiver vibrates for 0�5
seconds five times.
• Pattern 04:
The transceiver vibrates for 0�3
seconds eight times�
• Pattern 05 to 16: The transceiver vibrates, according
to the customized pattern�
NOTE: You can customize the Vibration pattern,
Vibration Repeat, and Interval time using the
programming software�
Vibration
Turns the Vibration function ON or OFF�
L To vibrate the transceiver, set each Vibration
setting to ON using the programming software�
Depending on the Vibration setting, the transceiver
may vibrate:
• When a call that includes a matching 2-Tone code is
received�
• When a call that includes a matching 5-Tone code is
received�
• When a Call Alert is received�
• When a Message is received�
• When a Status call that includes a matching status
number is received�
• When a DTMF code is received�
• When a user pushes a key�
• While in the Low Battery 1 state�
• While in the Low Battery 2 state�
• While in the Surveillance mode�
Key Vibration
Selects whether or not to vibrate the transceiver when
a user pushes a key�
L To use this function, the Vibration function must first
be turned ON�
Sensor
Man Dwn Ang
Sets the Emergency mode detection angle for the
Man Down function� If the transceiver leans past the
set angle for the ON Timer time period, the transceiver
enters the Emergency mode, and then a countdown
starts�
• Options: 45, 60, or 75 degrees
Motion Sense
Sets the acceleration sensor sensitivity to detect
whether the user is moving or not, for the Motion
Detection function� This setting is for the Motion
Detection function, and it determines the acceleration
threshold level to activate the Motion Detection Timer�
• Range: 1 (high sensitivity) ~ 10 (low sensitivity)�
L If you set a lower level, the transceiver will enter the
Emergency mode sooner�
Stat Sense
Sets the acceleration sensor sensitivity to detect if the
user is stationary or not for the Stationary Detection
function� This setting is used for the Stationary
Detection function, and it determines the acceleration
threshold level to activate the Stationary Detection's
ON Timer (Sec)�
• Range: 1 (high sensitivity) ~ 10 (low sensitivity)�
L If you set at a higher level, the transceiver will enter the
Emergency mode sooner�
• Sensitivity example
6-14
10
9
8
7
6
5
4
3
2
1