Setting Up Drives - Siemens SINUMERIK 840D sl Operating Manual

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Managing programs
12.12 Set up drives
12.12.2

Setting up drives

The "Set Up Drives" window is available in the "Start-up" operating area for configuration.
File
The created configuration data is stored in the "logdrive.ini" file. This file is located in the
/user/sinumerik/hmi/cfg directory.
General information
Entry
Type
Connection
Device
Partition
Port
Disconnect
Path
662
No drive
USB local
USB global
NW Windows/Linux
Local drive
FTP
Front
X203/X204
X204
Meaning
No drive defined.
Access to the USB memory medium is only realized via
the TCU to which it is connected.
USB drives are automatically identified if the memory
medium is inserted when SINUMERIK Operate powers-
up.
All of the TCUs in the plant network can access the USB
memory medium.
- USB global is not possible under Windows!
Network drive
Local drive
Hard disk or user memory on the CompactFlash card.
Access to an external FTP server.
USB interface that is located at the front of the operator
panel.
USB interface X203/X204 that is located at the rear of the
operator panel.
For SIMATIC Thin Client the USB interface is X204.
Names of the TCU to which the USB storage medium is
connected, e.g. tcu1. The NCU must already know the
TCU name.
Partition number on the USB memory medium, e.g. 1.
If a USB hub is used, specify the USB port of the hub.
Interface for the FTP connection. The default port is 21.
After a disconnect timeout, the FTP connection is
disconnected. The timeout can be between 1 and 150 s.
10 s is the default setting.
Start direct directory of the data carrier that is
connected via the local drive.
Network path to a directory that has been released in
the network. This path must always start with "//", e.g.
//Server01/share3.
Operating Manual, 03/2013, 6FC5398-8CP40-3BA1