Various Modes (Q406) - HEIDENHAIN TNC 620 User Manual

Cnc
Hide thumbs Also See for TNC 620:
Table of Contents

Advertisement

18
Touch Probe Cycles: Automatic Kinematics Measurement
18.4 MEASURE KINEMATICS (Cycle 451, DIN/ISO: G451, option)

Various modes (Q406)

Test mode Q406 = 0
The TNC measures the rotary axes in the positions defined and
calculates the static accuracy of the tilting transformation.
The TNC records the results of a possible position optimization
but does not make any adjustments.
Position Optimization mode Q406 = 1
The TNC measures the rotary axes in the positions defined and
calculates the static accuracy of the tilting transformation.
During this, the TNC tries to change the position of the rotary axis
in the kinematics model in order to achieve higher accuracy.
The machine data is adjusted automatically.
452
Position optimization of the rotary
axes with preceding, automatic
datum setting and measurement of
the rotary axis backlash
1 TOOL CALL "TCH PROBE" Z
2 TCH PROBE 451 MEASURE
KINEMATICS
Q406=1
;MODE
Q407=12.5
;SPHERE RADIUS
Q320=0
;SET-UP CLEARANCE
Q408=0
;RETR. HEIGHT
Q253=750
;F PRE-POSITIONING
Q380=0
;REFERENCE ANGLE
Q411=-90
;START ANGLE A AXIS
Q412=+90
;END ANGLE A AXIS
Q413=0
;INCID. ANGLE A AXIS
Q414=0
;MEAS. POINTS A AXIS
Q415=-90
;START ANGLE B AXIS
Q416=+90
;END ANGLE B AXIS
Q417=0
;INCID. ANGLE B AXIS
Q418=0
;MEAS. POINTS B AXIS
Q419=+90
;START ANGLE C AXIS
Q420=+270
;END ANGLE C AXIS
Q421=0
;INCID. ANGLE C AXIS
Q422=3
;MEAS. POINTS C AXIS
Q423=3
;NO. OF PROBE POINTS
Q431=1
;PRESET
Q432=0.5
;BACKLASH, ANG.
RANGE
TNC 620 | User's Manual Cycle Programming | 3/2014

Advertisement

Table of Contents
loading

Table of Contents