13.3
Touch probe table

General information

Various data is stored in the touch probe table that defines the
probe behavior during the probing process. If you run several touch
probes on your machine tool, you can save separate data for each
touch probe.

Editing touch probe tables

To edit the touch probe table, proceed as follows:
Select the Manual Operation mode
Select the touch probe functions: Press the
TOUCH PROBE soft key The TNC displays
additional soft keys
Select the touch probe table: Press the Tch probe
table soft key
Set the EDIT soft key to ON
Using the arrow keys, select the desired setting
Perform desired changes
Exit the touch probe table: Press the END soft key