Sony MVS-8000X User Manual page 314

Multi format switcher system with ccp-8000 series center control panel volume 2
Hide thumbs Also See for MVS-8000X:
Table of Contents

Advertisement

Notes
If you choose a register which already contains a snapshot, and save a
snapshot, then the existing register contents are overwritten.
The register number appears in the display. If the number is followed by a
letter 'e' or 'E,' this indicates the following.
e: The selected register is empty for the regions selected in step 3.
E: The selected register is empty for all currently selectable regions.
The entered register number appears in the display.
6
To apply attributes, press the following buttons, turning them on.
Attribute to apply
Effect dissolve
Auto transition
GPI output
a) The GPI port that can be set is 1 (fixed).
For details of attributes, see "Snapshot Attributes" (page 309).
Notes
In the numeric keypad control block, it is not possible to apply the cross-
point hold. For details, see "Applying snapshot attributes" (page 329).
7
Press the [ENTER] button.
This saves the snapshot, and the [STORE] button goes off. The [RCALL]
and [STORE STATS] buttons light.
To cancel a snapshot save operation
After saving a snapshot, to cancel the save, hold down the [STORE STATS]
button and press the [UNDO] button.
Recalling a snapshot from the numeric keypad control block
1
In the numeric keypad control block, press the [SNAPSHOT] button,
turning it on.
This allocates the numeric keypad control block to snapshot operations,
and the [RCALL] button lights.
2
Press the region selection button corresponding to the region you want to
recall, turning it on. Multiple selections are also possible.
Button
[+/–/EFF DISS] button
[CLR/AUTO TRANS] button
a)
[TRIM/GPI ENBL] button
Snapshot Operations From the Numeric Keypad Control Block
313

Advertisement

Table of Contents
loading

Table of Contents