6
Set the start point as a timecode value.
7
Press [Enter].
The new start point setting is reflected in the status area.
8
To set the stop point, in the <Stop TC> group press the [Set] button.
A timecode window appears.
If you do not want to set the stop point, skip to step 11.
9
Set the stop point as a timecode value.
10
Press [Enter].
The new stop point setting is reflected in the status area.
11
To set the variable speed, in the <Variable Speed> group, carry out either
of the following.
• Press [Fit].
Without setting a speed value, this automatically carries out playback
according to automatically calculated values for the duration and
keyframe duration to fit the set start point and stop point.
• Press the [Set] button, and adjust the parameter with the knob.
Knob
Parameter
2
Variable
a) The setting range of the variable speed depends on the type of connected device.
The new variable speed setting is reflected in the status area.
Repeat steps 2 to 11 as required for other devices.
To carry out start point and stop point settings and cueing up
operations in the device control block
With the following buttons in the device control block, you can set the start
point or stop point of a keyframe point on the timeline, or carry out a cueing up
operation.
Notes
• When using the device control block (trackball or joystick), check that the
[MENU] button in the block is lit amber. If it is not lit, press it, turning it on.
• When using the device control block (search dial), check that the
[TIMELINE] is lit amber.
Setting
Variable speed
Control of VTRs, Extended VTRs, and Disk Recorders
Setting values
a)
–100 to +200
219