Maximum value/minimum value reset completed flag
Medium speed
'Maximum value/minimum value reset completed flag' (XD) turns on after the maximum and minimum values stored in 'CH1
Maximum value' (Un\G404) and 'CH1 Minimum value' (Un\G406) are reset by turning on and off 'Maximum value/minimum
value reset request' (YD).
'CH1 Maximum value' (Un\G404)
'CH2 Minimum value' (Un\G406)
'Maximum value/minimum value reset
request' (YD)
'Maximum value/minimum value reset
completed flag' (XD)
Performed by the A/D converter module.
Performed by a program.
■Device number
The following shows the device number of this input signal.
Signal name
Maximum value/minimum value reset completed flag
A/D conversion completed flag
Common
'A/D conversion completed flag' (XE) turns on when the first A/D conversion of all the channels where the A/D conversion is
enabled is completed. To read digital output values, use this signal or 'A/D conversion completed flag' (Un\G42) as an
interlock.
■Device number
The following shows the device number of this input signal.
Signal name
A/D conversion completed flag
APPX
174
Appendix 2 I/O Signals
Simultaneous
Low speed
conversion
ON
Synchronization
OFF
ON
OFF
CH1
CH2
XD
CH1
CH2
XE
CH3
CH4
CH3
CH4