Un\G0 to Un\G399
Address
Address
(decimal)
(hexadecimal)
0
0H
1
1H
2
2H
3
3H
4 to 19
4H to 13H
20 to 35
14H to 23H
36
24H
37
25H
38
26H
39
27H
40
28H
41
29H
42
2AH
43 to 59
2BH to 3BH
60
3CH
61
3DH
62 to 69
3EH to 45H
70
46H
71
47H
72
48H
73 to 89
49H to 59H
90
5AH
91
5BH
92
5CH
93
5DH
94
5EH
95
5FH
96
60H
97
61H
98
62H
99
63H
100
64H
101 to 123
65H to 7BH
124 to 139
7CH to 8BH
140 to 155
8CH to 9BH
156 to 171
9CH to ABH
172 to 199
ACH to C7H
200 to 215
C8H to D7H
216 to 231
D8H to E7H
232 to 247
E8H to F7H
248 to 263
F8H to 107H
264 to 279
108H to 117H
280
118H
281 to 295
119H to 127H
296, 297
128H, 129H
298 to 301
12AH to 12DH
302
12EH
303 to 399
12FH to 18FH
*1 [n] in the table indicates an interrupt setting number. (n = 1 to 16)
APPX
180
Appendix 3 Buffer Memory Areas
Name
Latest error code
Latest address of error history
Latest alarm code
Latest address of alarm history
*1
Interrupt factor detection flag [n]
System area
Warning output flag (Process alarm upper limit)
Warning output flag (Process alarm lower limit)
Warning output flag (Rate alarm upper limit)
Warning output flag (Rate alarm lower limit)
Input signal error detection flag
System area
A/D conversion completed flag
System area
Operation mode monitor
Continuous logging status monitor
System area
RUN LED status monitor
ERR LED status monitor
ALM LED status monitor
System area
Level data 0
Level data 1
Level data 2
Level data 3
Level data 4
Level data 5
Level data 6
Level data 7
Level data 8
Level data 9
Continuous logging start/stop request
System area
*1
Interrupt factor mask [n]
System area
*1
Interrupt factor reset request [n]
System area
Interrupt factor generation setting [n]
System area
*1
Condition target setting [n]
System area
Condition target channel setting [n]
Continuous logging cycle setting value
System area
Mode switching setting
System area
Input signal error detection auto-clear enable/disable setting
System area
Default value
0
0
0
0
0
0000H
0000H
0000H
0000H
0000H
0000H
2
0
0000H
0000H
0000H
0
0
0
0
0
0
0
0
0
0
0
0
0
*1
0
0
*1
0
1
0
1
Data type
Auto refresh
Monitor
Monitor
Monitor
Monitor
Monitor
Monitor
Monitor
Monitor
Monitor
Monitor
Monitor
Monitor
Monitor
Monitor
Monitor
Monitor
Control
Control
Control
Control
Control
Control
Control
Control
Control
Control
Control
Control
Control
Setting
Setting
Setting
Setting
Setting
Setting

Advertisement

Table of Contents
loading