Chapter 4 Provisioning the TimeProvider

Setting Communications Parameters

Autonomous Message
A 1168 REPT EVT
HAS CHANGED,2003-10-24\""
;
Setting Communications Parameters
If you want to change the communications parameter values, use the ED-EQPT
command. The following sections describe the commands for performing each
individual task. For detailed information on the ED-EQPT command, see the
TimeProvider TL1 Reference Guide. Record the values you provision in

Setting RS-232 Parameters

This section describes how to set the baud rate, the handshaking mode, and echo
modes on the local and remote ports.
Setting the Baud Rate
Use the ED-EQPT command to provision the baud rate on the Local or Remote
port.
ED-EQPT:[<tid>]:<aid>:[<ctag>]::<keyword>=<value>;
This command has a default access level of ADMIN.
<aid>
<keyword>
COMp
p = L | R
BAUD
Sample Command
ED-EQPT::COML:TS1000::BAUD=9600;
This command sets the local Craft communications port to 9600 baud.
Normal Response
M
;
86
TimeProvider User's Guide
TP-SSU 03-10-24 10:08:28
SYS,EQPT:NA,DATCHG,NSA,03-10-24,10-08-28:\"SYSTEM DATE
<value>
2400 | 9600 |
19200 | 28800 |
38400 | 57600
TIMEPROVIDER 03-10-24 10:10:25
TS1000 COMPLD
Description
Communications ports
L = Local
R = Remote
Baud rate
097-58001-02 Revision C – August 2005
Table
4-3.
Default value