Setting the Handshaking (Flow) Mode
Use the ED-EQPT command to provision the handshaking mode on the local Craft
or Remote port to None, Hardware, Software, or Hardware/Software.
ED-EQPT:[<tid>]:<aid>:[<ctag>]::<keyword>=<value>;
This command has a default access level of ADMIN.
<aid>
<keyword>
COMp
p = L | R
FLOW
Sample Command
ED-EQPT::COML:TS1000::FLOW=HW;
Normal Response
M
;
Setting the Echo Mode
Use the ED-EQPT command to provision the echo mode on the local Craft or
Remote port to On or Off. When set to ENABLE, characters you type at the
keyboard also appear on the monitor. If one keystroke generates two characters on
the monitor, set this parameter to DISABLE.
You can also use this command to echo the <tid> in the response from the
TimeProvider.
ED-EQPT:[<tid>]:<aid>:[<ctag>]::<keyword>[=<value>];
This command has a default access level of ADMIN.
<aid>
<keyword>
COMp
p = L | R
ECHO
TIDQUIET
Sample Command
ED-EQPT::COML:TS1000::ECHO=ENABLE;
097-58001-02 Revision C – August 2005
<value>
NONE | SW |
HW | SWHW
TIMEPROVIDER 03-10-24 10:12:33
TS1000 COMPLD
<value>
ENABLE | DISABLE
ENABLE | DISABLE
Chapter 4 Provisioning the TimeProvider
Setting Communications Parameters
Description
Communications ports
Flow control
Description
Communications ports
Input echo
Enables or disables the
echo of the <tid>. This
is a session setting.
TimeProvider User's Guide
Default value
NONE
Default value
DISABLE
DISABLE
87