Provisioning the Outputs

This section describes the commands you use to provision the outputs of the
TimeProvider.

Enabling and Disabling the Outputs

Use the ED-EQPT command to enable or disable the output signal. This command
affects the specified group of eight output channels, or sixteen output channels if the
Expansion panel is also used; individual channels cannot be enabled or disabled.
ED-EQPT:[<tid>]:<aid>:[<ctag>]::<keyword>=<value>;
This command has a default access level of ADMIN.
<aid>
<keyword>
OUTg
g = A | B | C | D
OUTSTATE
Sample Command
ED-EQPT::OUTA:TS1000::OUTSTATE=DISABLE;
This command disables output group A and turns off all eight channels, or sixteen
channels if the Expansion panel is also used.
Autonomous Message
A 1189 REPT EVT
GROUP STATE HAS CHANGED,DISABLE\""
;

Provisioning the Output Framing Type

Use the ED-SYNC command to provision the output framing type.
CAS is the only available option for E1 output framing because the BITS/SSU clock
in the TimeProvider generates the highest density ones signal available.
Downstream Network Elements (NEs) configured to receive CAS or CCS will accept
the CAS output generated by the TimeProvider without errors.
ED-SYNC:[<tid>]:<aid>:[<ctag>]::<keyword>=<value>;
097-58001-02 Revision C – August 2005
<value>
ENABLE
DISABLE
TP-SSU 03-10-24 11-09-12
"OUTA,EQPT:NA,OUTSTATE,NSA,03-10-24 11-09-12:\"OUTPUT
Chapter 4 Provisioning the TimeProvider
Description
Select the output group
Enable the specified
output group
Disable the specified
output group
TimeProvider User's Guide 111
Provisioning the Outputs
Default value
ENABLE