Chapter 4 Provisioning the TimeProvider
Provisioning the IOC
Sample Command
RTRV-SYS-MODE:::TS1000;
Normal Response
M
;

Setting the IOC Parameters

Use the ED-EQPT command to provision each IOC. This command allows you to
select which IOC is Active and which is Standby; to switch the Active and Standby
IOCs; to place a IOC "In Service" or "Out of Service"; and to define the oscillator type
to Type I or ST3E for a quartz-based IOC or to Type II or ST2 for a Rubidium IOC.
ED-EQPT:[<tid>]:<aid>:[<ctag>]::<keyword>=<value>;
This command has a default access level of ADMIN.
<aid>
<keyword>
IOCm
m = 1 | 2
IOCMODE
IOCACTV
IOCSTATE
CLKTYPE
Sample Command
ED-EQPT::IOC1:TS1000::IOCSTATE=INSERV;
This command places IOC 1 in the "In Service" mode. Use this command when you
have taken an IOC out of service and are now ready to put it back in service.
98
TimeProvider User's Guide
TP-SSU 03-10-24 10:37:54
TS1000 COMPLD
SSU
<value>
ACTIVE |
STANDBY
n/a
INSRV
OOSRV
ST2/TYPEII |
ST3/TYPEI
Description
IOC module
Sets the mode of the specified
IOC. For redundant systems,
changing the state of one IOC
forces the other IOC to the
alternate state
Sets the Standby IOC to Active
Places an "Out of Service" IOC
in the "In Service" mode
(restarts)
Places an "In Service" IOC in the
"Out of Service" mode. An Out of
Service IOC cannot generate
outputs or monitor inputs and
does not generate alarms
Defines the Local Oscillator
type. Selects the type of clock
used to generate SSMs in
Holdover mode
097-58001-02 Revision C – August 2005
Default value
ACTIVE
n/a
INSERV
TYPEI