Field
event id
alarm level
Sample Command
RTRV-ATTR::SYS:TS1000;
This command causes the TimeProvider to return the alarm levels associated with
all system-level alarms.
Normal Response
M
;

Retrieving Current Alarms

You can display the current active alarms using the RTRV-ALM command.
RTRV-ALM:[<tid>]:<aid>:[<ctag>];
This command has a default access level of USER.
ALL (or null)
SYS
IMC
IOCm (m = 1 | 2)
PRS
INPp (p = 1 | 2)
OUTg (g = A | B | C | D)
097-58001-02 Revision C – August 2005
The identifier of the alarm whose level is displayed
The value indicates the alarm level that is generated by an alarm
event:
NR = Not Reported
NA = A non-alarm event
MN = Minor alarm
MJ = Major alarm
CR = Critical alarm
TP-SSU 03-10-24 11:21:20
TS1000 COMPLD
"SYS:IOC1EQPT,NA"
"SYS:IOC2EQPT,NA"
"SYS:PWRA,MJ"
"SYS:PWRB,MJ"
"SYS:EXTALM1,MJ"
"SYS:EXTALM2,CR"
"SYS:EXPFAIL,MJ"