Setting Ethernet Parameters
Set up the Ethernet port, if you are using it, by following the procedure in
Ethernet
Parameters, on page 93.
Setting User Security
Set up the user security (usernames and passwords), if you are using it, by
following the procedure in
Setting Communications Parameters
If you want to change the communications parameter values, use the ED-EQPT
command. The following sections describe the commands for performing each
individual task. For detailed information on the ED-EQPT command, see the
TimeProvider TL1 Reference Guide. Record the values you provision in
Setting RS-232 Parameters
This section describes how to set the baud rate, the handshaking mode, and echo
modes on the local and remote ports. The default values are 9600 baud, No flow
control, echo mode disabled, tidquiet disabled.
Setting the Baud Rate
Use the ED-EQPT command to provision the baud rate on the Local or Remote port.
ED-EQPT:[<tid>]:<aid>:[<ctag>]::<keyword>=<value>;
This command has a default access level of ADMIN.
<aid>
<keyword>
COMp
BAUD
p = L | R
Sample Command
ED-EQPT::COML:TS1000::BAUD=9600;
This command sets the local Craft communications port to 9600 baud.
Normal Response
M
;
097-58001-02 Revision G – April 2008
Defining the Security
<value>
2400 | 9600 | 19200 |
28800 | 38400 | 57600 |
115200
TIMEPROVIDER 03-10-24 10:10:25
TS1000 COMPLD
Chapter 4 Provisioning the TimeProvider
Setting Communications Parameters
Parameters, on page 94.
Description
Default value
Baud rate
9600
TimeProvider User's Guide
Setting
Table
4-4.
91