Default Mask Parameters - Symmetricom TimeProvider 1000 User Manual

Edge clock
Hide thumbs Also See for TimeProvider 1000:
Table of Contents

Advertisement

<aid>
<keyword>
GPS, PRS,
INP1, INP2
MASK
MTIE-1
MTIE-5
MTIE-10
MTIE-50
MTIE-100
MTIE-500
FFOFF-60
Table 4-2. Default Mask Parameters
MTIE-1
Default
10 000
GPS-R
150
PRS
10
DS1
302
OCN
600
PRC
25
TYPE I
750
TYPE II
302
Sample Command
SET-TH::GPS:TS1000::MASK=GPS-R;
This command sets the GPS input performance monitoring threshold to a mask
value of GPS-R.
097-58001-02 Revision C – August 2005
<value>
DEFAULT
GPS-R
PRS
DS1
OCN
PRC
TYPEI
TYPEII
1 to 5 000 000
1 to 5 000 000
1 to 5 000 000
1 to 5 000 000
1 to 5 000 000
1 to 5 000 000
100 to 10 000 000
MTIE-5
MTIE-10
50 000
100 000
150
150
10
12
312
325
1000
1000
25
25
750
1000
312
325
Chapter 4 Provisioning the TimeProvider
Provisioning the Input Reference
Description
System level
Set the MTIE-x and FFOFF-60 thresholds to
predefined settings.
values for each setting.
1-second MTIE observation threshold in ns
5-second MTIE observation threshold in ns
10-second MTIE observation threshold in ns
50-second MTIE observation threshold in ns
100-second MTIE observation threshold in ns
500-second MTIE observation threshold in ns
Set FFOFF threshold for 60-second
calculation period, in ps/s
MTIE-50
MTIE-100
500 000
1 000 000
150
150
25
39
325
550
1000
1000
25
39
2000
2000
425
1000
Table 4-2
describes the
MTIE-500
FFOFF-60
5 000 000
10 000 000
155
50 000
155
1000
1002
12 000
1002
370 000
155
1000
2000
2900
1000
1000
TimeProvider User's Guide 109

Advertisement

Table of Contents
loading

This manual is also suitable for:

Timeprovider 1100

Table of Contents