ND-CLK NETWORK TIME PROTOCOL ANALOG CLOCK (Series II) USER MANUAL Symmetricom, Inc. Tel: 707-528-1230 Santa Rosa, CA 95403 Sep-08 Printed in USA...
Page 2
The information contained in this document is subject to change without notice. Symmetricom, Inc. (hereinafter SYMMETRICOM) makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. SYMMETRICOM shall not be liable for errors contained here in or for incidental or consequential damages in connection with the furnishing, performance, or use of this material.
Protocol) client. It is designed to display time referenced to either an internal NTP time server, or one located on the Internet. The ND-CLK contains a stepper motor drive with advanced microprocessor and electronics to rapidly and automatically synchronize the hands on the face of the clock to an accurate NTP (Network Time Protocol) time server.
INSTALLATION Operating Environment The ND-CLK is not water or moisture proof. Treat it as you would any other delicate electronic device and do not expose it to water, excessive heat or physical abuse. The ND-CLK contains a stepper motor and microprocessor control electronics designed to operate in indoors environments.
Pre-Installation Checklist Before installing a ND-CLK, one should be prepared with the following basic configuration information that the device will require. It may be necessary to obtain some or all of this information from a network administrator in your organization.
Page 7
Maximum distance is 100m/328ft [Important Note: the ND-CLK with an installed POE (Power Over Ethernet) option, will obtain its power directly from a POE powered source using the spare wires of a standard network cable with RJ45 connector for input power. The POE source must be a fully compliant IEEE 802.3af PSE operating at +48VDC.
Page 8
Important Note: The hands of the ND-CLK cannot be set manually. Do not attempt to open the clock to access the hands. This action will violate your warranty. This device has no user serviceable parts inside. The position of the hands has been factory set and is retained in non-volatile memory.
Mounting The ND-CLK is designed for surface mounting on a wall. Power and/or low voltage signal wiring should be provided and installed according to local electrical codes to access the clock from the rear. A mounting bracket is supplied which has been designed to fit on either a standard 2”x 4”...
Display Behavior The ND-CLK may take up to 20 minutes to set the time, depending on the current internal [local] time and the hand positions. If the ND-CLK’s hands do not move to the correct time within 20 minutes, check the section entitled Troubleshooting Tips.
[Note: The IP address of the unit is required to configure the ND clock with Telnet.] [Helpful Hint: The DHCP server can be utilized to provide the IP address of the associated device name that is registered. ] ® ND-CLK User Manual- Rev 1.0.1 - Sep-08 Symmetricom , Inc...
[Note: Factory default: Automatic daylight savings time is disabled. You must enable and configure the settings to display local time with DST.] ® ND-CLK User Manual- Rev 1.0.1 - Sep-08 Symmetricom , Inc...
This protocol only operates in a LAN setting, but is required if you wish to be able to join a multicast group on a host. IGMP is defined in 2236. ® ND-CLK User Manual- Rev 1.0.1 - Sep-08 Symmetricom , Inc...
Page 14
In addition, you may want to read RFC 2588: IP Firewalls. ] Multicast and Anycast The network clock does not currently provide anycast capability. ® ND-CLK User Manual- Rev 1.0.1 - Sep-08 Symmetricom , Inc...
Basic operation of the network clock is configured via the WinDiscovery software supplied with the clock, or via Telnet if the IP address of the clock is known. Only one configuration method should be used at a time. ® ND-CLK User Manual- Rev 1.0.1 - Sep-08 Symmetricom , Inc...
When complete, a list of device families and groups will be displayed in the left pane of the main WinDiscovery window. ND-CLK clocks are analog time display members of the “Symmetricom, Inc. NTP Clocks” family.
Page 17
Apply and OK button to accept changes that you have made. Use the Cancel button to exit the screen without applying changes. [NOTE: Cancel does not undo changes that have been saved using the Apply button.] ® ND-CLK User Manual- Rev 1.0.1 - Sep-08 Symmetricom , Inc...
Page 18
To utilize static IP addressing, de-select the checkbox for “Automatically obtain network configuration from DHCP/BOOTP”. You must enter the IP address, Netmask, Gateway, Primary DNS, and may enter a Secondary DNS. ® ND-CLK User Manual- Rev 1.0.1 - Sep-08 Symmetricom , Inc...
Page 19
[Hint: You can change the device name to one convenient for your site – preferably one that helps you to later identify the exact physical location of the device. ] Administrative Hub [Note: the Administrative Hub configuration item is reserved for future use.] ® ND-CLK User Manual- Rev 1.0.1 - Sep-08 Symmetricom , Inc...
Page 20
The top right section of the Window shows a snapshot of the network clock display, constantly updated. This update is not precise, but is meant to give you a view of the clock display for troubleshooting and maintenance purposes. ® ND-CLK User Manual- Rev 1.0.1 - Sep-08 Symmetricom , Inc...
Page 21
The network clock can configured to listen to NTP broadcasts by Listen for NTP broadcasts selecting the “Listen for NTP via broadcast address [255,255,255,255]” checkbox. The Broadcast/Multicast timeout period (in minutes) is adjustable when this mode is selected. ® ND-CLK User Manual- Rev 1.0.1 - Sep-08 Symmetricom , Inc...
Page 22
D multicast addresses or groups from 224.0.0.0 to 239.255.255.255 . These groups or class D ® ND-CLK User Manual- Rev 1.0.1 - Sep-08 Symmetricom , Inc...
Page 23
Select the Time Zone and click OK to close the window. Changes are not applied until you click OK or the Apply button on the main Configuration window. ® ND-CLK User Manual- Rev 1.0.1 - Sep-08 Symmetricom , Inc...
Page 24
US/Canada DST standard [adopted Spring 2007] EU DST standard Click OK to close the Window. The DST rules will be applied when you click OK or Apply on the main Configuration window. ® ND-CLK User Manual- Rev 1.0.1 - Sep-08 Symmetricom , Inc...
Page 25
NTP time server, or the clock begins acting erratically; try returning the advanced settings to the default values shown above.] ® ND-CLK User Manual- Rev 1.0.1 - Sep-08 Symmetricom , Inc...
Page 26
[Note: The visual determination of the accuracy of the hand display should be done by comparing the clock hands only after the ND-CLK indicates that it is synchronized to NTP, and then only to a digital display, from an accurate locked NTP server or synchronized digital display clock placed next to the ND-CLK.]...
Page 27
Warning: If the password is lost, the user must reset the clock using the Reset button on the rear of the clock. This will cause the clock to return all configuration to factory-default settings. ® ND-CLK User Manual- Rev 1.0.1 - Sep-08 Symmetricom , Inc...
Page 28
Upon you next session, you will not be prompted for a password for the clock.] [Helpful Hint: Use the global password feature to avoid entering and remembering individual passwords during each WinDiscovery session. See the appendix for additional information] ® ND-CLK User Manual- Rev 1.0.1 - Sep-08 Symmetricom , Inc...
Page 29
[Note: for the purpose of refreshing its internal clock, the network clock assumes the time entered is UTC. Any configured time zone/daylight time settings will then be applied to this time for display purposes.] ® ND-CLK User Manual- Rev 1.0.1 - Sep-08 Symmetricom , Inc...
Page 30
Near the bottom of the Status window the error will be displayed. (If there is no error the error text field will not be displayed] ® ND-CLK User Manual- Rev 1.0.1 - Sep-08 Symmetricom , Inc...
Page 31
NTP broadcast timeout. For example, if the NTP broadcast timeout is increased to 60 minutes the soft restart timeout will also be increased to 60 minutes. ® ND-CLK User Manual- Rev 1.0.1 - Sep-08 Symmetricom , Inc...
PC with which you are accessing it. A login prompt is presented if a password has been configured for the device. The configuration menu will be displayed when the correct password has been provided. ® ND-CLK User Manual- Rev 1.0.1 - Sep-08 Symmetricom , Inc...
Page 33
You have the choice of using DHCP for automatic IP Configuration or entering the data in these screens for Static IP addressing. By factory default, the clock is set to DHCP address mode. ® ND-CLK User Manual- Rev 1.0.1 - Sep-08 Symmetricom , Inc...
Page 34
NTP will automatically overwrite any manually established time/date. Therefore, practical use of this feature requires the clock to be removed from the network, or for NTP server configuration to be left undefined. ® ND-CLK User Manual- Rev 1.0.1 - Sep-08 Symmetricom , Inc...
Page 35
DHCP IP addressing mode by default, and will likely change the IP address of the unit, making the communication via telnet impossible until the new IP address of the unit is configured or known. ® ND-CLK User Manual- Rev 1.0.1 - Sep-08 Symmetricom , Inc...
Page 36
The ND-CLK analog stepper motor clock has a calibration feature. Use this option to calibrate the hands of the clock to the displayed time The ND-CLK analog clock hands have been pre-set and aligned at the factory. This hand location and alignment information is retained in non-volatile flash. Under normal circumstances it should not be necessary to adjust or align the hands.
Problem: Clock(s) previously found during a recent session of WinDiscovery do not show up during the current session. Problem: The clock status or settings displayed under WinDiscovery show garbled characters. ® ND-CLK User Manual- Rev 1.0.1 - Sep-08 Symmetricom , Inc...
Page 38
169.254.xxx.xxx. Near the bottom of the Status window the error will be displayed. (If there is no error the text box will not be displayed.) ® ND-CLK User Manual- Rev 1.0.1 - Sep-08 Symmetricom , Inc...
Page 39
IP address conflict. The clock will reset its address (fallback) to one within the link-local address space (169.254.xxx.xxx). If you see that the IP address starts with 169.254, obtain a new IP address for the clock or resolve the ® ND-CLK User Manual- Rev 1.0.1 - Sep-08 Symmetricom , Inc...
Page 40
Problem: The hands are running fast (at a rate of 1 revolution every two seconds for the minute hand). Problem: The hands are running in reverse, or the hands are jumping to another time. Problem: The red status LED is flashing. ® ND-CLK User Manual- Rev 1.0.1 - Sep-08 Symmetricom , Inc...
Page 41
Possible Reasons/solutions: 1. The ND-CLK is in a rapid adjust mode. During this time period the red status LED will blink/flash once per second. This is normal operation for the clock. 2. Upon acquisition of NTP during initial startup, or a change to the internal time...
Page 42
If these troubleshooting tips do not solve your problem, contact customer service at: support@symmetricom.com or call: ….. 888-367-7966 in the USA ….. 408-428-7907 worldwide ® ND-CLK User Manual- Rev 1.0.1 - Sep-08 Symmetricom , Inc...
AC power consumption........<10 W Protection…..........Built in fuse, output power limiting, over voltage, and short circuit protection. Caution: there are no user serviceable parts inside the ND-CLK. Please contact the factory if you require servicing or repair. Power Requirements POE Model Power Over Ethernet Input Voltage ....
Compliance Models: ND-CLK ,with 12 or 12/24 face , AC and POE versions, This equipment has been tested and found to comply with the radiated and line conducted limits for a Class B digital device. These limits are designed to provide reasonable protection against harmful interference in a commercial/residential installation.
Limitation of Liability By purchasing any product from Symmetricom, the Buyer consents to and agrees that the Buyer' s sole and exclusive remedy for any damages or losses incurred by the Buyer, as a result of Symmetricom' s breach of its one-year Limited Warranty for defects in materials...
(available on the right click menu of the item). The global password does not overwrite the existing password for a device, therefore any device with a different password cannot be administered.] ® ND-CLK User Manual- Rev 1.0.1 - Sep-08 Symmetricom , Inc...
Turn of the global password feature in WinDiscovery by deselecting the “Enable Global Password” checkbox. • It is not necessary to delete the information from the global password field. ® ND-CLK User Manual- Rev 1.0.1 - Sep-08 Symmetricom , Inc...
“Set Password” command. (Available under the right click menu for each device) • Enter the new password information and select the “Change Password” button. • Repeat for each device in the group that is to use the global password. ® ND-CLK User Manual- Rev 1.0.1 - Sep-08 Symmetricom , Inc...
Page 49
• Re-enable the global password feature by selecting the “Enable Global Password” checkbox. • Enter the new global password. ® ND-CLK User Manual- Rev 1.0.1 - Sep-08 Symmetricom , Inc...
• DON' T ever use benzene, gasoline, acetone, methyl ethyl ketone (MEK), muriatic acid, or carbon tetrachloride on the polycarbonate lens. • DON' T clean polycarbonate lenses in hot sun or on very hot days. ® ND-CLK User Manual- Rev 1.0.1 - Sep-08 Symmetricom , Inc...
Page 51
When the clock is first installed, glazing compound and masking tape adhesive can be easily removed from the lens by applying naphtha (VM&P) or kerosene with a soft cloth, followed immediately with a thorough soap and water cleaning. DO NOT USE GASOLINE. ® ND-CLK User Manual- Rev 1.0.1 - Sep-08 Symmetricom , Inc...
APPENDIX C - MOUNTING The ND-CLK is designed for surface mounting on a wall. A mounting bracket is supplied which has been designed to fit on either a standard 2”x 4” or 4” x 4” conduit box or wiring compartment.