Testing The Reference Switching; Testing The Non-Revertive Operating Mode - Symmetricom TimeProvider 1000 User Manual

Edge clock
Hide thumbs Also See for TimeProvider 1000:
Table of Contents

Advertisement

Testing the Reference Switching

To test the ability of the TimeProvider to switch references, you perform a two-step
test:
Connect appropriate reference inputs to the TimeProvider.
Create a fault on the selected reference signal and observe that the
TimeProvider changes to the appropriate secondary input.
To test the reference switching:
1. Connect a suitable reference signal to the PRS input and a second reference
signal to the INP1 input. Wait for the Qualified LEDs for both inputs to turn green
and for the Active LED to light on the PRS input.
2. Issue the
input and force the TimeProvider to switch to the INP1 reference.
3. Observe that the Active LED changes from the original input to the secondary
input (PRS to INP1 or INP1 to PRS).

Testing the Non-Revertive Operating Mode

When the TimeProvider is in the non-revertive operating mode, the input reference
signal does not revert to the original input after it recovers from an error condition.
The TimeProvider is in non-revertive mode when the QLEVEL parameter for INP1,
INP2, and PRS inputs is set to the same value, and the PRIORITY parameters for
the same inputs are set to the same level.
To test the non-revertive operating mode, perform the following steps:
1. Define the non-revertive mode by setting the QLEVEL and PRIORITY
parameters to appropriate values. See
104, and
2. Provision and connect appropriate reference inputs to the TimeProvider.
3. Create a fault on the selected reference signal and observe that the
TimeProvider changes to the appropriate secondary input.
4. Remove the fault on the initial reference signal and observe that the
TimeProvider does not revert to that initial reference input. The event log
indicates that the reference signal is no longer in fault.
097-58001-02 Revision C – August 2005
ED-EQPT::PRS:::INSTATE=DISABLE;
Setting the Input Priority
Chapter 5 Testing the TimeProvider
command to disable the PRS
Setting the Input Quality
Level, on page 105, for further information.
Testing Alarm Conditions
Level, on page
TimeProvider User's Guide 139

Advertisement

Table of Contents
loading