Chapter 4 Provisioning the TimeProvider
Provisioning the Input Reference

Enabling CRC4

Use the ED-SYNC command to enable or disable the use of CRC4 on E1 inputs.
ED-SYNC:[<tid>]:<aid>:[<ctag>]::<keyword>=<value>;
This command has a default access level of ADMIN.
<aid>
<keyword>
INPp
p = 1 | 2
CRCENA
Sample Command
ED-SYNC::INP1:TS1000::CRCENA=ENABLE;
Normal Response
A 1188 REPT EVT
CHANGED,ENABLE\""
;

Using Performance Monitoring

You can set thresholds for alarms and for qualifying inputs using MTIE and FFOFF
data. For more information on performance monitoring, see
Monitoring, on page 25.
Setting MTIE and FFOFF Thresholds
Use the SET-TH command to set the alarm thresholds for each input and each
MTIE window.
SET-TH:[<tid>]:<aid>:[<ctag>]::<keyword>=<value>;
This command has a default access level of ADMIN.
108 TimeProvider User's Guide
<value>
ENABLE |
DISABLE
TP-SSU 03-10-24 11:06:57
"INP1,T1:NA,CRCENA,NSA,03-10-24 11-06-57:\"INPUT CRC HAS
Description
System inputs
Provisions the use of
CRC4 on E1 inputs
Performance
097-58001-02 Revision C – August 2005
Default value
DISABLE