Provisioning The Retimer Module - Symmetricom TimeProvider 1000 User Manual

Edge clock
Hide thumbs Also See for TimeProvider 1000:
Table of Contents

Advertisement

Chapter 4 Provisioning the TimeProvider
Provisioning the Outputs
This command has a default access level of ADMIN.
<aid>
<keyword>
OUTg
g = A | B | C | D
FRMTYPE
Sample Command
ED-SYNC::OUTA:TS1000::FRMTYPE=CAS;
This command provisions output group A to an E1, CAS framing format.
Autonomous Message
A 1190 REPT EVT
FRAMING TYPE HAS CHANGED,CAS\""
;

Provisioning the Retimer Module

Use the ED-EQPT command to enable or disable the Retimer module or port when
it is installed in one of the output slots on the Main shelf.
ED-EQPT:[<tid>]:<aid>:[<ctag>]::<keyword>=<value>;
This command has a default access level of ADMIN.
<aid>
<keyword>
RTMg[-p]
g = A | B | C | D
p = 1 | 2
RTMSTATE
Sample Command
ED-EQPT::RTMA:TS1000::RTMSTATE=ENABLE;
This command enables the Retiming module installed in Group A.
112 TimeProvider User's Guide
<value>
2M | CAS | D4 | ESF |
CC | JCC | JCC4 | 8K
| ISOLATED_1 |
1.544 MHz | 6.312
MHz
TP-SSU 03-10-24 11:11:18
"OUTA,EQPT:NA,FRMTYPE,NSA,03-10-24 11-11-18:\"OUTPUT
<value>
ENABLE | DISABLE
Description
System inputs
Provisions the output
framing
Description
Retimer group or port
Enables or disables
the specified module
or port
097-58001-02 Revision C – August 2005
Default value
2M
Default value
Enable

Advertisement

Table of Contents
loading

This manual is also suitable for:

Timeprovider 1100

Table of Contents