Setting The Input Priority Level; Manually Selecting The Reference - Symmetricom TimeProvider 1000 User Manual

Edge clock
Hide thumbs Also See for TimeProvider 1000:
Table of Contents

Advertisement

Autonomous Message
A 1183 REPT EVT
ASSIGNED QUALITY LEVEL HAS CHANGED,1\""
;

Setting the Input Priority Level

The PRIORITY level works together with the QLEVEL parameter (described in
Setting the Input Quality
The PRIORITY level is the second factor the TimeProvider uses to determine which
input to use when the original primary input becomes unavailable.
Use the ED-SYNC command to set the PRIORITY level of the selected reference.
ED-SYNC:[<tid>]:<aid>:[<ctag>]::<keyword>=<value>;
This command has a default access level of ADMIN.
<aid>
<keyword>
PRS
INPp (p = 1 | 2)
PRIORITY
GPS
Sample Command
ED-SYNC::PRS:TS1000::PRIORITY=2;
ED-SYNC::INP1:TS1000::PRIORITY=2;
ED-SYNC::INP2:TS1000::PRIORITY=2;
These commands set the PRIORITY for each input to the same value; if you also
provision the QLEVEL to the same value, then you set up a non-revertive switching
strategy.
Autonomous Message
A 1184 REPT EVT
HAS CHANGED,2\""
;

Manually Selecting the Reference

Use the ED-SYNC command to manually select the reference. To select the
reference, you must first set the REFMODE keyword to FORCED, as described in
Controlling Automatic Reference
ED-SYNC:[<tid>]:<aid>:[<ctag>]::<keyword>=<value>;
097-58001-02 Revision C – August 2005
TP-SSU 03-10-24 10:54:44
"PRS,EQPT:NA,QLEVEL,NSA,003-10-24 10-54-44:\"USER
Level, on page 104) to determine the switching strategy.
<value>
2 | 3 | 4
TP-SSU 03-10-24 10:56:00
"PRS,EQPT:NA,PRIORITY,NSA,03-10-24 10-56-00:\"PRIORITY
Switching, on page 102.
Chapter 4 Provisioning the TimeProvider
Provisioning the Input Reference
Description
Input ports
Sets the priority for
1
the selected input
TimeProvider User's Guide 105
Default value