Lcd Display - YASKAWA U1000 Series Technical Manual

Low harmonics regenerative matrix converter
Hide thumbs Also See for U1000 Series:
Table of Contents

Advertisement

4.2 Using the Digital Operator

◆ LCD Display

Figure 4.2
No.
Name
1
Operation Mode Menus
DriveWorksEZ Function
2
Selection
3
Mode Display Area
4
Ready
5
Data Display
Frequency Reference
6
Assignment
<1>
7
LO/RE Display
<2>
Function Key 1
8
(F1)
9
FWD/REV
Function Key 2
10
(F2)
<1> Displayed when in Frequency Reference Mode.
<2> Displayed when in Frequency Reference Mode and Monitor Mode.
134
1
2
MODE
DWEZ
FREF
U1-01=
U1-02=60.00Hz
U1-03=10.50A
JOG
FWD
8
9
Figure 4.2 LCD Display
Table 4.1 Display and Contents
Display
MODE
Displayed when in Mode Selection.
MONITR
Displayed when in Monitor Mode.
VERIFY
Indicates the Verify Menu.
PRMSET
Displayed when in Parameter Setting Mode.
A.TUNE
Displayed during Auto-Tuning.
SETUP
Displayed when in Setup Mode.
DWEZ
Displayed when DriveWorksEZ is being used.
DRV
Displayed when in Drive Mode.
PRG
Displayed when in Programming Mode.
Rdy
Indicates the drive is ready to run.
Displays specific data and operation data.
OPR
Displayed when the frequency reference is assigned to the LCD Operator.
AI
Displayed when the frequency reference is assigned to the drives Analog Input.
COM
Displayed when the frequency reference is assigned to the drives MEMOBUS/Modbus Communication Inputs.
OP
Displayed when the frequency reference is assigned to a drive Option Unit.
RP
Displayed when the frequency reference is assigned to the drives Pulse Train Input.
RSEQ
Displayed when the reference is supplied from a remote source.
LSEQ
Displayed when the reference is supplied from the operator keypad.
RREF
Displayed when the frequency reference is supplied from a remote source.
LREF
Displayed when the frequency reference is supplied from the operator keypad.
JOG
Pressing
F1
HELP
Pressing
F1
Pressing
F1
HOME
Pressing
F1
ESC
Pressing
F1
FWD
Indicates forward motor operation.
REV
Indicates reverse motor operation.
FWD/REV
Pressing
F2
DATA
Pressing
F2
Pressing
F2
RESET
Pressing
F2
3
4
DRV Rdy
(OPR)
60.0Hz
LSEQ
LREF
FWD / REV
10
Content
runs the motor at the Jog frequency.
displays the Help menu.
scrolls the cursor to the left.
returns to the top menu (Frequency Reference).
returns to the previous display.
switches between forward and reverse.
scrolls to the next display.
scrolls the cursor to the right.
resets the existing drive fault or error.