General Description - YASKAWA U1000 Series Technical Manual

Low harmonics regenerative matrix converter
Hide thumbs Also See for U1000 Series:
Table of Contents

Advertisement

1.2

General Description

◆ U1000 Model Selection
Refer to
Table 1.1
for drive selection depending on Normal Duty (ND) or Heavy Duty (HD) rating.
Note: The models and capacities in shown here are based on standard settings and operation conditions. Higher carrier frequencies and
higher ambient temperatures require derating.
3-Phase 200 V Class
Heavy Duty Rating (HD)
Model
Rated Output
CIMR-U
20028
20042
20054
20068
20081
20104
20130
20154
20192
20248
Note: Current derating is required when setting the carrier frequency higher.
details.
YASKAWA ELECTRIC SIEP C710636 02B YASKAWA U1000 Technical Manual
Table 1.1 U1000 Models
Normal Duty Rating (ND)
Rated Output
Current (A)
Current (A)
22
28
28
42
42
54
54
68
68
81
81
104
104
130
130
154
154
192
192
248
1.2 General Description
3-Phase 400 V Class
Heavy Duty Rating (HD)
Model
Rated Output
CIMR-U
Current (A)
40011
9.6
40014
11
40021
14
40027
21
40034
27
40040
34
40052
40
40065
52
40077
65
40096
77
40124
96
40156
124
40180
156
40216
180
40240
216
40302
240
40361
302
40414
361
40477
414
40590
477
40720
590
40900
720
40930
900
Refer to Carrier Frequency Derating on page 462
Normal Duty Rating (ND)
Rated Output
Current (A)
11
14
21
27
34
40
52
65
77
96
124
156
180
216
240
302
361
414
477
590
720
900
930
for
1
31

Advertisement

Table of Contents
loading

Table of Contents