YASKAWA U1000 Series Technical Manual page 537

Low harmonics regenerative matrix converter
Hide thumbs Also See for U1000 Series:
Table of Contents

Advertisement

No.
Units
E1-03
0
1
2
Hz
50.0
60.0
60.0
E1-04
E1-05
V
200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0
<18>
E1-06
Hz
50.0
60.0
50.0
E1-07
Hz
2.5
3.0
3.0
E1-08
V
12.0
12.0
12.0
<18>
E1-09
Hz
1.3
1.5
1.5
E1-10
V
6.0
6.0
6.0
<18>
<14> Default setting value is dependent on the motor code set to parameter E5-01.
<18> Values shown here are for 200 V class drives. Double the value when using a 400 V class drive.
<42> Default settings for E1-04 through E1-10 (E3-04 through E3-10 for motor 2).
<44> The default value shown here is for the following localized drives: Japan (Model code: CIMR-UA), India (Model code: CIMR-UD), Asia
(Model code: CIMR-UT). For default value of China localized drive (Model code: CIMR-UB), refer to
Localized Drive: CIMR-UB
Table B.8 Default Values of the China Localized Drive: CIMR-UB
Parameter
E1-04
Maximum Output Frequency
E1-06
E1-07
Middle Output Frequency
E1-09
Minimum Output Frequency
E3-04
Motor 2 Max Output Frequency
E3-06
Motor 2 Base Frequency
E3-07
Motor 2 Mid Output Frequency
E3-09
Motor 2 Minimum Output Frequency
<14> Default setting value is dependent on the motor code set to parameter E5-01.
YASKAWA ELECTRIC SIEP C710636 02B YASKAWA U1000 Technical Manual
Table B.7 E1-03 V/f Pattern Settings for Drive Capacity:
CIMR-U20248; CIMR-U40156 to 40930
V/f
3
4
5
6
7
72.0
50.0
50.0
60.0
60.0
60.0
50.0
50.0
60.0
60.0
3.0
25.0
25.0
30.0
30.0
12.0
35.0
50.0
35.0
50.0
1.5
1.3
1.3
1.5
1.5
6.0
5.0
6.0
5.0
6.0
on page
537.
Description
V/f, V/f w/PG
50.0 Hz
Base Frequency
50.0 Hz
2.5 Hz
1.3 Hz
50.0 Hz
50.0 Hz
2.5 Hz
1.3 Hz
8
9
A
B
C
50.0
50.0
60.0
60.0
90.0
120.0 180.0
50.0
50.0
60.0
60.0
60.0
60.0
2.5
2.5
3.0
3.0
3.0
15.0
20.0
15.0
20.0
12.0
12.0
1.3
1.3
1.5
1.5
1.5
7.0
9.0
7.0
11.0
6.0
Control Mode (A1-02, E3-01)
OLV
CLV
50.0 Hz
50.0 Hz
50.0 Hz
50.0 Hz
3.0 Hz
0.0 Hz
0.5 Hz
0.0 Hz
50.0 Hz
50.0 Hz
50.0 Hz
50.0 Hz
3.0 Hz
0.0 Hz
0.5 Hz
0.0 Hz
B.5 V/f Pattern Default Values
OLV
F
D
E
<42>
60.0
60.0
60.0
<44>
<44>
200.0
200.0
60.0
60.0
60.0
60.0
<44>
<44>
3.0
3.0
3.0
3.0
0.0
<44>
<44>
12.0
12.0
11.0
1.5
1.5
1.5
0.5
0.0
<44>
<44>
6.0
6.0
6.0
2.0
Default Values of the China
OLV/PM
AOLV/PM
<14>
<14>
<14>
<14>
<14>
<14>
OLV/PM
CLV
AOLV/PM
CLV/PM
<44>
<14>
<14>
<44>
<14>
<44>
0.0
<44>
<14>
0.0
CLV/PM
<14>
<14>
0.0 Hz
B
537

Advertisement