Knob Parameter
1
5
2
Press [Delay Set].
This confirms the delay value, which is reflected in the status area.
Interfacing With External Devices (Device Interface
Menu)
To carry out setup relating to connections with external devices, display the
Switcher>Device Interface menu.
To display the Device Interface menu
In the Engineering Setup menu, select VF3 'Switcher' and HF7 'Device
Interface.'
Making 9-pin port device interface settings
The description in this section takes the REMOTE3 port as an example. For
other REMOTE ports, carry out the same process as required.
1
In the Switcher>Device Interface menu, press [Remote Assign].
The Remote Assign menu appears.
2
Select the device interface you want to set for the REMOTE3 port from the
<Remote3> group.
Editor A: assign Editor A to the REMOTE3 port.
Editor B: assign Editor B to the REMOTE3 port.
AUX: assign AUX to the REMOTE3 port.
DME1: assign DME1 to the REMOTE3 port.
Note
When REMOTE3 and REMOTE4 are respectively assigned to DME1 and
DME2, you can switch the AUX bus from the DME (DME-3000/7000)
connected to these ports.
At this time, connect the DME input video signals and key signals as
follows.
Adjustment
GPI Port
GPI output port for the
setting
Delay
Delay value for the output
port
Setting values
1 to 8
0 to 300 (fields)
Setup Relating to Switcher Processor
261