Sony MVS-8000 User Manual page 263

With ccp-8000 series center control panel
Hide thumbs Also See for MVS-8000:
Table of Contents

Advertisement

• Turn the knobs to make the setting.
Knob
3
4
a) • Action list when the trigger type is other than "Level"
• Action list when the trigger type is "Level"
b) When knob 3 selection is "Key Snapshot"
c) When knob 3 selection is "Snapshot" or "Effect"
6
Press [Action Set] to confirm the action selection.
The selected setting appears in the status area.
Carrying out level settings
To set the low level and high level, first set the trigger type to "Level," then use
the following procedure.
1
In the Switcher>Device Interface menu, select the action to be set, and
press [H/L Set].
The H/L Set menu appears.
2
Using any of the following methods, select the settings.
• Press directly on the list appearing in the status area.
• Press the arrow keys to scroll the reverse video cursor.
Parameter
Adjustment
Action
Action selection
Reg No
Register number
When Target is M/E-1, M/E-2, or M/E-3: Cut, Auto Trans
Key1 Cut, Key1 Auto Trans, Key2 Cut, Key2 Auto Trans, Key3 Cut, Key3 Auto
Trans, Key4 Cut, Key4 Auto Trans
SS ? Recall, Key1 SS ? Recall, Key2 SS ? Recall, Key3 SS ? Recall, Key4 SS ?
Recall
Effect ? Recall, Effect ? Recall & Run, KF Run, KF Stop, KF Rewind, KF Reverse
Run, No Action
When Target is P/P: Cut, Auto Trans
DSK1 Cut, DSK1 Auto Trans, DSK2 Cut, DSK2 Auto Trans, DSK3 Cut, DSK3
Auto Trans, DSK4 Cut, DSK4 Auto Trans
FTB Cut, FTB Auto Trans
SS ? Recall, DSK1 SS ? Recall, DSK2 SS ? Recall, DSK3 SS ? Recall, DSK4 SS
? Recall
Effect ? Recall, Effect ? Recall & Run, KF Run, KF Stop, KF Rewind, KF Reverse
Run, No Action
When Target is Common/Setup: FM Src1 Field Freeze, FM Src1 Frame Freeze, FM
Src2 Field Freeze, FM Src2 Frame Freeze
FM Src1 Freeze Off, FM Src2 Freeze Off
User1 to 8 SS ? Recall, User1 to 8 EFF ? Recall, User1 to 8 EFF ? Recall & Run,
User1 to 8 KF Run, User1 to 8 KF Stop, User1 to 8 KF Rewind, User1 to 8 KF
Reverse Run, No Action
When Target is M/E-1, M/E-2, M/E-3, or P/P: Aspect, No Action
When Target is Common/Setup: Format, Aspect, No Action
Setting values
a)
1 to ...
b)
1 to 4
c)
1 to 99
Setup Relating to Switcher Processor