Sony MVS-8000 User Manual page 269

With ccp-8000 series center control panel
Hide thumbs Also See for MVS-8000:
Table of Contents

Advertisement

3
In the <Trigger Type> group, select the trigger polarity.
high.
No Operation: Apply no trigger on an input pulse.
4
In the <Target> group, select what this applies to (channels 1 to 4, or Proc).
5
Using any of the following methods, select the action to be set.
• Press directly on the list appearing in the status area.
• Press the arrow keys to scroll the reverse video cursor.
• Turn the knobs to make the setting.
Knob
3
4
a) • Action list when the trigger type is other than "Level"
• Action list when the trigger type is "Level"
b) When knob 3 selection is "Snapshot"
c) When knob 3 selection is "Effect"
6
Press [Action Set] to confirm the action selection.
The selected setting appears in the status area.
Carrying out level settings
To set the low level and high level, first set the trigger type to "Level," then use
the following procedure.
1
In the DME>Device Interface menu, select the action to be set, and press
[H/L Set].
The H/L Set menu appears.
: Apply the trigger on a rising edge of an input pulse.
: Apply the trigger on a falling edge of an input pulse.
: Apply the trigger on a change in the polarity of the input signal.
(Level): Carry out the specified operation when the input is low or
Parameter
Adjustment
Action
Action selection
Reg No
Register number
When Target is Ch1, Ch2, Ch3, or Ch4: Freeze, SS ? Recall
Effect ? Recall, Effect ? Recall & Run, KF Run, KF Stop, KF Rewind, KF Reverse
Run, No Action
When Target is Proc: No Action
When Target is Ch1, Ch2, Ch3, or Ch4: Aspect, No Action
When Target is Proc: Format (frame/field rate, number of lines)
Aspect, No Action
Setting values
a)
1 to ...
b)
1 to 99
c)
1 to 399
269