Table ‎ 8 -2
Table ‎ 8 -3
82
13
14
O_S_OVER
15
O_P_OVER
19
O_P_HI
20
O_P_LO
21
O_NG
22
O_INDEX
23
O_EOM
Input Pins
Handler Interface Signals ~ Input Pins
Pin
Pin names
24
I_E_TRIG
25
I_K_LOCK
Power Pins
Handler Interface Signals ~ Power Pins
Pin
Pin names
16,18 GND
17
VCC
NC
Over fail occurs on the secondary
measurement parameter. Active
low. (The signal on this pin is
available only after AUX is turned
on.)
Over fail occurs on the primary
measurement parameter. Active
low. The logic state of this pin =
O_P_HI OR O_P_LO.
Hi fail occurs on the primary
measurement parameter. Active
low.
Low fail occurs on the primary
measurement parameter. Active
low.
The overall test result is an over
fail. Active low. The logic state of
this pin = O_S_OVER OR
O_P_OVER.
This pin indicates that AD
conversion is still ongoing. It is not
yet finished when it is low.
A low level on this pin indicates
that the test is still ongoing and not
yet finished.
Signal descriptions
External trigger input, Active on a
rising edge.
Key pad lock signal. Low on this
pin locks the key pad on the front
panel while a high level on this pin
unlocks the key pad.
Signal descriptions