Table of Contents

Advertisement

Parameter
Query Response
Example

11.12.3 LIST:BAND

The LIST:BAND command sets the List Sweep point value, limit mode and
low/high limit values.
Command
Syntax
Parameter
Example
Query Syntax
Parameter
Query Response
Example
116
Where,<n> is:
n
NR1(1 to 10): List sweep point
{on,off}
SEND> LIST:STAT? 1<NL>
RET>
on<NL>
LIST:BAND <n>,<point value>,{A,B,OFF},<low>,
<high>
Where, <n>,<point value>,{A,B,OFF},<low>,<high>
is:
n
NR1(1 to 10): List sweep point
<point value>
or signal level voltage value)
A
Uses the primary parameter as the limit
parameter.
B
Uses the secondary parameter as the limit
parameter.
OFF
Turn off the List Sweep's comparator function
<low>
NR1,NR2 or NR3: low limit value
<high> NR1,NR2 or NR3: high limit value
Note: The suffix multipliers can be used with this
command. But the suffix units CANNOT be added.
SEND> LIST:BAND 1,1k,A,1n,2n<NL>
SEND> LIST:BAND 2,10k,A,1E-9,2E-9<NL>
LIST:BAND? <n>
Where,<n> is:
n
NR1(1 to 10): List sweep point
{on,off},<point value>,{A,B,-
},<NR3:low>,<NR4:high>
SEND> LIST:BAND? 1<NL>
RET>
on,1.00000e+03,A,1.000000E-9,2.000000E-
9<NL>
Sweep point value (frequency value