PSU [0] Fan Speed ---> 17441 RPM
Test 4.000 - Psu Fan Speed Monitor Test ............................. PASS
diagS3240GetPsuOnStatus[580]: ERROR: PSU-1 is not present...
diagS3240PsuFanSpeedMonitorTest[378]: ERROR: Getting PSU -1 power status failed..
Test 4.001 - Psu Fan Speed Monitor Test ............................. FAIL
Test 4 - Psu Fan Speed Monitor Test ................................ FAIL
+ TEST - 5
PSU [0] Source Type --> AC
Test 5.000 - Psu Source type test ................................... PASS
diagS3240GetPsuOnStatus[580]: ERROR: PSU-1 is not present...
diagS3240PsuSourceTypeTest[517]: ERROR: Getting PSU -1 power status failed..
Test 5.001 - Psu Source type test ................................... FAIL
Test 5 - Psu Source Type Test ...................................... FAIL
+ TEST - 6
PSU [0] Fan FLOW Type Normal (IO --> Rear)
Test 6.000 - Psu Fan module type detect test ........................ PASS
diagS3240GetPsuOnStatus[580]: ERROR: PSU-1 is not present...
diagS3240PsuFanModuleTypeDetectTest[448]: ERROR: Getting PSU -1 power status failed.
The following example shows how to run offline diagnostics in Debug mode.
NOTE: Dell Networking highly recommends reloading the system after running the offline diagnostics in Debug mode.
Dell#diag stack-unit 0 level0 verbose no-reboot
Warning - diagnostic execution will cause multiple link flaps on the peer side - advisable
to shut
directly connected ports
Warning - It is highly recommended to reboot the system after Offline Diagnostics
Proceed with Diags [confirm yes/no]: y
00:37:32: %Z9000:0 %DIAGAGT-6-DA_DIAG_STARTED: Starting diags on stack unit 0
Dell#00:37:32 : Approximate time to complete the Diags ... 1 Min 30 Sec
Dell#
WARNING: Reboot is highly recommended after running Offline Diagnostics in Debug Mode.
Debug Mode can be
used only for troubleshooting specific test issue.
The following example shows the show diag information command.
Dell#
Dell#show diag information -
Diag information:
Diag software image version:
9-0-0-23
-------------------------------------------------------------------
Stack-unit Member 0:
Stack-unit Member 1:
Stack-unit Member 2:
Stack-unit Member 3:
Stack-unit Member 4:
Stack-unit Member 5:
Stack-unit Member 6:
Stack-unit Member 7:
-------------------------------------------------------------------
The following example shows the show diag stack-unit command.
Dell#show diag stackunit 0
Diag status of Stackunit member 0:
------------------------------------------------------------------
Stackunit is currently offline.
Stackunit level2 diag issued at Thu Apr 09, 2009 02:40:13 PM.
Current diag status:
Duration of execution (Total):
Diagonostic test results located: /f10/flash/TestReport-SU-0.txt
--------------------------------------------------------------------
CPU Version : Intel I386
Stack Unit Board temperature : 30 Degree C
Stack Unit Number : 0
824
Z-Series Debugging and Diagnostics
Unit diags are done (Stackunit Offline).
Not present.
Not present.
Not present.
Not present.
Not present.
Not present.
Not present.
Unit diags are done.
8 min 11 sec.