point to another new destination (for example, 1/4). If you attempt to configure another destination (to create 5 MG port), this
message displays: % Error will be thrown in case of RPM and ERPM features.
Example of Changing the Destination Port in a Monitoring Session
Dell(conf-mon-sess-5)#do show moni session
SessID
Source
------
------
1
Te 1/1
2
Te 1/1
3
Te 1/1
4
Te 1/1
5
Te 1/1
Dell(conf-mon-sess-5)#
Dell(conf)#mon ses 300
Dell(conf-mon-sess-300)#source tengig 1/17 destination tengig 1/4 direction tx
% Error: Exceeding max MG ports for this MD port pipe.
Dell(conf-mon-sess-300)#
Dell(conf-mon-sess-300)#source tengig 1/17 destination tengig 1/1 direction tx
Dell(conf-mon-sess-300)#do show mon session
SessionID Source
Destination Direction Mode
--------- ------
----------- --------- ----
0
Te 1/13 Te 2/1
10
Te 1/14 Te 2/2
20
Te 1/15 Te 2/3
30
Te 1/16 Te 2/7
300
Te 1/17 Te 1/1
Dell(conf-mon-sess-300)#
Example of Configuring Another Monitoring Session with a Previously Used Destination Port
Dell(conf)#mon ses 300
Dell(conf-mon-sess-300)#source TenGig 1/17 destination TenGig 1/4 direction tx
% Error: Exceeding max MG ports for this MD port pipe.
Dell(conf-mon-sess-300)#
Dell(conf-mon-sess-300)#source TenGig 1/17 destination TenGig 1/1 direction tx
Dell(conf-mon-sess-300)#do show mon session
SessionID Source
Destination Direction Mode
--------- ------
----------- --------- ----
0
Te 1/13 Te 1/1
10
Te 1/14 Te 1/2
20
Te 1/15 Te 1/3
30
Te 1/16 Te 1/7
300
Te 1/17 Te 1/1
Example of Viewing a Monitoring Session
In the example below, 0/25 and 0/26 belong to Port-pipe 1. This port-pipe has the same restriction of only four destination ports,
new or used.
Dell(conf-mon-sess-300)#do show mon session
SessionID Source
Destination Direction Mode
--------- ------
----------- --------- ----
0
Te 1/13 Te 1/1
10
Te 1/14 Te 1/2
20
Te 1/15 Te 1/3
30
Te 1/16 Te 1/37
100
Te 1/25 Te 1/38
110
Te 1/26 Te 1/39
300
Te 1/17 Te 1/1
Dell(conf-mon-sess-300)#
Given these parameters, the following illustration shows the possible port monitoring configurations on the S-Series.
Destination
-----------
Te 2/1
Te 2/2
Te 2/3
Te 2/4
Te 2/5
rx
interface Port-based
rx
interface Port-based
rx
interface Port-based
rx
interface Port-based
tx
interface Port-based
rx
interface Port-based
rx
interface Port-based
rx
interface Port-based
rx
interface Port-based
tx
interface Port-based
rx
interface Port-based
rx
interface Port-based
rx
interface Port-based
rx
interface Port-based
tx
interface Port-based
tx
interface Port-based
tx
interface Port-based
Dir
Mode
Source IP
---
----
---------
both Port
N/A
both Port
N/A
both Port
N/A
both Port
N/A
both Port
N/A
Type
----
Type
----
Type
----
Dest IP
--------
N/A
N/A
N/A
N/A
N/A
Port Monitoring