Configuring An Edgeport; Flush Mac Addresses After A Topology Change - Dell Force10 Z9000 Configuration Manual

Hide thumbs Also See for Force10 Z9000:
Table of Contents

Advertisement

To view the current values for these interface parameters, use the show config command from INTERFACE mode.

Configuring an EdgePort

The EdgePort feature enables interfaces to begin forwarding traffic approximately 30 seconds sooner.
In this mode, an interface forwards frames by default until it receives a BPDU that indicates that it should behave otherwise; it does
not go through the Learning and Listening states. The bpduguard shutdown-on-violation option causes the interface
hardware to be shut down when it receives a BPDU. When you implement only bpduguard, although the interface is placed in an
Error Disabled state when receiving the BPDU, the physical interface remains up and spanning-tree drops packets in the hardware
after a BPDU violation. BPDUs are dropped in the software after receiving the BPDU violation. This feature is the same as PortFast
mode in spanning tree.
CAUTION: Configure EdgePort only on links connecting to an end station. EdgePort can cause loops if you enable it on
an interface connected to a network.
To enable EdgePort on an interface, use the following command.
Enable EdgePort on an interface.
INTERFACE mode
spanning-tree mstp edge-port [bpduguard | shutdown-on-violation]
Dell Networking OS Behavior: Regarding bpduguard shutdown-on-violation behavior:
– If the interface to be shut down is a port channel, all the member ports are disabled in the hardware.
– When you add a physical port to a port channel already in the Error Disable state, the new member port is also disabled in the
hardware.
– When you remove a physical port from a port channel in the Error Disable state, the error disabled state is cleared on this
physical port (the physical port is enabled in the hardware).
– The reset linecard command does not clear the Error Disabled state of the port or the Hardware Disabled state. The
interface continues to be disabled in the hardware.
– You can clear the Error Disabled state with any of the following methods:
* Use the shutdown command on the interface.
* Disable the shutdown-on-violation command on the interface (using the no spanning-tree stp-id
portfast [bpduguard | [shutdown-on-violation]] command).
* Disable spanning tree on the interface (using the no spanning-tree command in INTERFACE mode).
* Disabling global spanning tree (using the no spanning-tree command in CONFIGURATION mode).
Example of Enabling an EdgePort on an Interface
To verify that EdgePort is enabled, use the show config command from INTERFACE mode.
Dell(conf-if-te-3/11)#spanning-tree mstp edge-port
Dell(conf-if-te-3/11)#show config
!
interface TenGigabitEthernet 3/11
no ip address
switchport
spanning-tree mstp edge-port
spanning-tree MSTI 1 priority 144
no shutdown
Dell(conf-if-te-3/11)#

Flush MAC Addresses after a Topology Change

Dell Networking OS has an optimized MAC address flush mechanism for RSTP, MSTP, and PVST+ that flushes addresses only when
necessary, which allows for faster convergence during topology changes.
However, you may activate the flushing mechanism defined by 802.1Q-2003 using the tc-flush-standard command, which
flushes MAC addresses after every topology change notification.
Multiple Spanning Tree Protocol (MSTP)
459

Advertisement

Table of Contents
loading

Table of Contents