Configuring The Protocol Type Value For The Outer Vlan Tag; Configuring Dell Networking Os Options For Trunk Ports - Dell Force10 Z9000 Configuration Manual

Hide thumbs Also See for Force10 Z9000:
Table of Contents

Advertisement

Example of Viewing VLAN Stack Member Status
To display the status and members of a VLAN, use the show vlan command from EXEC Privilege mode. Members of a VLAN-
Stacking-enabled VLAN are marked with an M in column Q.
Dell#show vlan
Codes: * - Default VLAN, G - GVRP VLANs
NUM
Status
Q Ports
* 1
Active
U Te 3/0-5,18
2
Inactive
3
Inactive
4
Inactive
5
Inactive
6
Active
M Po1(Te 3/14-15)
M Te 3/13
Dell#

Configuring the Protocol Type Value for the Outer VLAN Tag

The tag protocol identifier (TPID) field of the S-Tag is user-configurable.
To set the S-Tag TPID, use the following command.
Select a value for the S-Tag TPID.
CONFIGURATION mode
vlan-stack protocol-type
The default is 9100.
To display the S-Tag TPID for a VLAN, use the show running-config command from EXEC privilege mode. Dell Networking OS
displays the S-Tag TPID only if it is a non-default value.

Configuring Dell Networking OS Options for Trunk Ports

802.1ad trunk ports may also be tagged members of a VLAN so that it can carry single and double-tagged traffic.
You can enable trunk ports to carry untagged, single-tagged, and double-tagged VLAN traffic by making the trunk port a hybrid port.
To configure trunk ports, use the following commands.
1.
Configure a trunk port to carry untagged, single-tagged, and double-tagged traffic by making it a hybrid port.
INTERFACE mode
portmode hybrid
2.
Add the port to a 802.1Q VLAN as tagged or untagged.
INTERFACE VLAN mode
[tagged | untagged]
Example of Configuring a Trunk Port as a Hybrid Port and Adding it to Stacked VLANs
In the following example, TenGigabitEthernet 1/1 is a trunk port that is configured as a hybrid port and then added to VLAN
100 as untagged VLAN 101 as tagged, and VLAN 103, which is a stacking VLAN.
Dell(conf)#interface tenigabitethernet 1/1
Dell(conf-if-te-1/1)#portmode hybrid
Dell(conf-if-te-1/1)#switchport
Dell(conf-if-te-1/1)#vlan-stack trunk
Dell(conf-if-te-1/1)#show config
!
interface TenGigabitEthernet 1/1
no ip address
portmode hybrid
Service Provider Bridging
667

Advertisement

Table of Contents
loading

Table of Contents