Mitsubishi Electric NZ2EX2B-60AD4 User Manual page 42

Cc-link ie field network analog-digital converter module
Table of Contents

Advertisement

Type
Decimal
256, 257
258
259
260
261
262
263
264
265
266 to 269
270
271
272
273
274
275
276
Main module
277
Module-based
parameter data
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297 to 511
Extension module 1
Module-based
512 to 767
parameter data
768 to 1279
*1
This value is the value of factory default or the value of initialization by Parameter area initialization command (address:
1002H).
*2
This shows whether reading/writing data from/to a program is possible.
R: Readable
W: Writable
*3
This shows the items enabled by turning on and off Initial data setting request flag (RY9).
40
Address
Hexadecimal
0100H, 0101H
System area
0102H
A/D conversion enable/disable setting
0103H
Range setting
0104H
Averaging process setting
CH1 Time average/Count average/Moving
0105H
average
CH2 Time average/Count average/Moving
0106H
average
CH3 Time average/Count average/Moving
0107H
average
CH4 Time average/Count average/Moving
0108H
average
0109H
Input signal error detection setting
010AH to 010DH
System area
010EH
Alert output setting
010FH
CH1 Process alarm lower lower limit value
0110H
CH1 Process alarm lower upper limit value
0111H
CH1 Process alarm upper lower limit value
0112H
CH1 Process alarm upper upper limit value
0113H
CH2 Process alarm lower lower limit value
0114H
CH2 Process alarm lower upper limit value
0115H
CH2 Process alarm upper lower limit value
0116H
CH2 Process alarm upper upper limit value
0117H
CH3 Process alarm lower lower limit value
0118H
CH3 Process alarm lower upper limit value
0119H
CH3 Process alarm upper lower limit value
011AH
CH3 Process alarm upper upper limit value
011BH
CH4 Process alarm lower lower limit value
011CH
CH4 Process alarm lower upper limit value
011DH
CH4 Process alarm upper lower limit value
011EH
CH4 Process alarm upper upper limit value
011FH
Digital clipping enable/disable setting
0120H
Scaling enable/disable setting
0121H
CH1 Scaling lower limit value
0122H
CH1 Scaling upper limit value
0123H
CH2 Scaling lower limit value
0124H
CH2 Scaling upper limit value
0125H
CH3 Scaling lower limit value
0126H
CH3 Scaling upper limit value
0127H
CH4 Scaling lower limit value
0128H
CH4 Scaling upper limit value
0129H to 01FFH
System area
The remote buffer memory areas of the
0200H to 02FFH
connected extension module are assigned.
0300H to 04FFH
System area
Description
0000H
0000H
0000H
0
0
0
0
0000H
000FH
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
000FH
000FH
0
0
0
0
0
0
0
0
Default
Necessity
*2
Read/Write
*1
value
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
*3
of RY9