[Sysname-GigabitEthernet1/0/1] poe pd-description IP Phone For Room 101
poe pd-policy priority
Use poe pd-policy priority to enable PI power management.
Use undo poe pd-policy priority to restore the default.
Syntax
poe pd-policy priority
undo poe pd-policy priority
Default
PI power management is disabled.
Views
System view
Predefined user roles
network-admin
Usage guidelines
If PI power management is disabled, the PSE does not supply power to new PDs when PSE power
overload occurs.
If PI power management is enabled, when a PSE is overloaded, the PSE allocates power to PDs
based on the priority of their PIs.
Examples
# Enable PI power management.
<Sysname> system-view
[Sysname] poe pd-policy priority
Related commands
poe priority
poe priority
Use poe priority to set the power supply priority for a PI.
Use undo poe priority to restore the default.
Syntax
poe priority { critical | high | low }
undo poe priority
Default
The power supply priority of a PI is low.
Views
PI view
PoE profile view
Predefined user roles
network-admin
148