Info-Center Logging Suppress Module - HPE FlexNetwork 5130 HI Series Network Management And Monitoring Command Reference

Hide thumbs Also See for FlexNetwork 5130 HI Series:
Table of Contents

Advertisement

%Jan
1 07:30:19:643 2000 Sysname ARP/6/DUPIFIP:
Duplicate address 172.16.0.1 on interface Vlan-interface100, sourced from 00e0-0058-123d
This message repeated 20 times in last 2 minutes.
The output shows that the second suppression period lasts for 2 minutes.
%Jan
1 07:30:20:541 2000 Sysname ARP/6/DUPIFIP:
Duplicate address 172.16.0.1 on interface Vlan-interface100, sourced from 00e0-0058-123d
This message repeated 1 times in last 1 second.
%Jan
1 07:30:19:542 2000 Sysname CFGMAN/5/CFGMAN_CFGCHANGED:
-EventIndex=[12]-CommandSource=[2]-ConfigSource=[4]-ConfigDestination=[2];
Configuration is changed.
The output shows that a different log is generated during the suppression period.
%Jan
1 07:30:24:643 2000 Sysname ARP/6/DUPIFIP:
Duplicate address 172.16.0.1 on interface Vlan-interface100, sourced from 00e0-0058-123d
%Jan
1 07:30:55:645 2000 Sysname ARP/6/DUPIFIP:
Duplicate address 172.16.0.1 on interface Vlan-interface100, sourced from 00e0-0058-123d
This message repeated 4 times in last 30 seconds.
The output shows that the system starts another suppression period.

info-center logging suppress module

Use info-center logging suppress module to configure a log suppression rule for a module.
Use undo info-center logging suppress module to delete a log suppression rule.
Syntax
info-center logging suppress module module-name mnemonic { all | mnemonic-value }
undo info-center logging suppress module module-name mnemonic { all | mnemonic-value }
Default
The device does not suppress output of any logs from any modules.
Views
System view
Predefined user roles
network-admin
Parameters
module-name: Specifies a log source module by its name, a case-insensitive string of 1 to 8
characters. To view the list of available log source modules, use the info-center logging suppress
module ? command.
mnemonic { all | mnemonic-value }: Configures a mnemonic filter for log suppression.
all: Suppresses output of all logs of the module.
mnemonic-value: Suppresses output of logs with the specified mnemonic value. The
mnemonic-value argument is a case-insensitive string of 1 to 32 characters, which must be the
complete value contained in the mnemonic field of the log message. Log suppression will fail if
a partial mnemonic value is specified.
Usage guidelines
You can configure log suppression rules to filter out the logs that you are not concerned with. A log
suppression rule suppresses output of all logs or only logs with a specific mnemonic value for a
module.
340

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents