Nqa Schedule - HPE FlexNetwork 5130 HI Series Network Management And Monitoring Command Reference

Hide thumbs Also See for FlexNetwork 5130 HI Series:
Table of Contents

Advertisement

Examples
# Enable the NQA client.
<Sysname> system-view
[Sysname] nqa agent enable
Related commands
nqa server enable

nqa schedule

Use nqa schedule to configure scheduling parameters for an NQA operation.
Use undo nqa schedule to stop the operation.
Syntax
nqa schedule admin-name operation-tag start-time { hh:mm:ss [ yyyy/mm/dd | mm/dd/yyyy ] | now }
lifetime { lifetime | forever } [ recurring ]
undo nqa schedule admin-name operation-tag
Default
No schedule is configured for an NQA operation.
Views
System view
Predefined user roles
network-admin
Parameters
admin-name operation-tag: Specifies an NQA operation by its administrator name and operation tag.
The admin-name argument represents the name of the administrator who creates the NQA operation.
The operation-tag argument represents the operation tag. Each of the arguments is a
case-insensitive string of 1 to 32 characters that cannot contain hyphens (-).
start-time: Specifies the start time and date of the NQA operation.
hh:mm:ss: Specifies the start time of an NQA operation.
yyyy/mm/dd: Specifies the start date of an NQA operation. The default value is the current system
time, and the value for the yyyy argument is in the range of 2000 to 2035.
mm/dd/yyyy: Specifies the start date of an NQA operation. The default value is the current system
time, and the value for the yyyy argument is in the range of 2000 to 2035.
now: Starts the operation immediately.
lifetime: Specifies the duration of an operation.
lifetime: Specifies the duration of an operation in seconds. The value range is 1 to 2147483647.
forever: Performs the operation until you stop it by using the undo nqa schedule command.
recurring: Runs the operation automatically at the start time and for the specified duration. If you do
not specify this keyword, the NQA operation is performed only once at the specified date and time.
Usage guidelines
The NQA operation works between the specified start time and the end time (the start time plus
operation duration). If the specified start time is ahead of the system time, the operation starts
immediately. If both the specified start time and end time are ahead of the system time, the operation
does not start. To display the current system time, use the display clock command.
49