HPE FlexNetwork 5130 HI Series Network Management And Monitoring Command Reference page 212

Hide thumbs Also See for FlexNetwork 5130 HI Series:
Table of Contents

Advertisement

network-operator
Parameters
entry-number: Specifies an alarm entry index in the range of 1 to 65535. If you do not specify an entry,
the command displays all private alarm entries.
Examples
# Display information about all RMON private alarm entries.
<Sysname> display rmon prialarm
PrialarmEntry 1 owned by user1 is VALID.
Sample type
Variable formula
Description
Sampling interval (in seconds) : 10
Rising threshold
Falling threshold
Alarm sent upon entry startup
Entry lifetime
Latest value
Table 48 Command output
Field
PrialarmEntry entry-number
owned by owner is status.
Sample type
Variable formula
Description
Sampling interval
Rising threshold
Falling threshold
associated with event
Alarm sent upon entry
startup
: absolute
: (.1.3.6.1.2.1.16.1.1.1.6.1*100/.1.3.6.1.2.1.16.1.1.1.5.1)
: ifUtilization.GigabitEthernet1/0/1
: 80(associated with event 1)
: 5(associated with event 2)
: risingOrFallingAlarm
: forever
: 85
Description
Alarm entry owner and status:
entry-number—Alarm entry index.
owner—Entry owner.
status—Entry status:
VALID—The entry is valid.
UNDERCREATION—The entry is invalid.
The status field is not configurable at the CLI. All alarm entries created from
the CLI are valid by default.
The display rmon prialarm command can display invalid entries, but the
display current-configuration and display this commands do not display
their settings.
Sample type:
absolute.
delta.
Variable formula.
Description of the alarm.
Interval (in seconds) at which data is sampled.
Alarm rising threshold.
Alarm falling threshold.
Event index associated with the alarm..
Alarm that can be generated at the first sampling:
risingAlarm.
fallingAlarm.
risingOrFallingAlarm.
The default is risingOrFallingAlarm.
203