HPE FlexNetwork 5130 HI Series Network Management And Monitoring Command Reference page 106

Hide thumbs Also See for FlexNetwork 5130 HI Series:
Table of Contents

Advertisement

Field
Clock status
Reference clock ID
VPN instance
Local mode
local poll interval
Description
Status of the clock source corresponding to this association:
configured—The association was created by a
configuration command.
dynamic—The association is established dynamically.
master—The clock source is the primary reference source
of the current system.
selected—The clock source has survived the clock selection
algorithm.
candidate—The clock source is the candidate reference
source.
sane—The clock source has passed authentication and will
be used as a reference clock.
insane—The clock source has not passed authentication, or
it has passed authentication but will not be used as a
reference clock.
valid—The clock source is valid, which means the clock
source meets the following requirements:
It has been authenticated and synchronized.
Its stratum level is valid.
Its root delay and root dispersion values are within their
ranges.
invalid—The clock source is invalid.
unsynced—The clock source has not been synchronized or
the value of the stratum level is invalid.
Reference clock ID of the NTP server:
If the reference clock is the local clock, the value of this field
is related to the value of the Clock stratum field:
When the value of the Clock stratum field is 0 or 1, this
field displays LOCL.
When the Clock stratum field has another value, this
field displays the IP address of the local clock.
If the reference clock is the clock of another device on the
network, this field displays the IP address of the device. If the
device supports IPv6, this field displays the MD5 digest of
the first 32 bits of the IPv6 address of the device. If this field
displays INIT, the local device has not established a
connection with the NTP server.
VPN instance to which the NTP server belongs. If the NTP server
is in a public network, the field displays Not specified.
This field is not supported in the current software version.
Operation mode of the local device:
unspec—The mode is unspecified.
active—Active mode.
passive—Passive mode.
client—Client mode.
server—Server mode.
broadcast—Broadcast or multicast server mode.
bclient—Broadcast or multicast client mode.
Polling interval of the local device, in seconds. The value
displayed is a power of 2. For example, if the displayed value is 6,
the poll interval of the local device is 2
97
6
, or 64 seconds.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents