Connecting the mains cable
General
If no mains cable is connected, a mains cable that is suitable for the connection voltage
must be fitted before commissioning.
A universal strain-relief device for cable diameters from 12 - 30 mm (0.47 - 1.18 in.) is fitted
to the power source.
Strain-relief devices for other cable cross-sections must be designed accordingly.
Stipulated mains
Power source
cables
TPS 320i /nc
TPS 320i /MV/nc
TPS 320i /600V/nc **
TPS 400i /nc
TPS 400i /MV/nc
TPS 400i /600V/nc **
TPS 500i /nc
TPS 500i /MV/nc
TPS 500i /600V/nc **
TPS 600i /nc
TPS 600i /600V/nc **
*
**
AWG = American wire gauge
Connecting the
mains cable -
general
46
Mains voltage
3 x 400 V
3 x 460 V
3 x 230 V
3 x 460 V
3 x 575 V
3 x 400 V
3 x 460 V
3 x 230 V
3 x 460 V
3 x 575 V
3 x 400 V
3 x 460 V
3 x 230 V
3 x 460 V
3 x 575 V
3 x 400 V
3 x 460 V
3 x 575 V
Cable type for USA / Canada: Extra-hard usage
Power source without CE mark; not available in Europe
CAUTION! Risk of injury and material damage due to short circuits.
Short circuits can occur between the phase conductors or between the phase
conductors and the ground conductor unless ferrules are used.
Fit ferrules to all phase conductors in an exposed mains cable as well as the
ground conductor.
NOTE! Mains cables must be connected to devices in compliance with national
standards and guidelines and the work must be carried out by a qualified person.
Cable cross-section
USA / Canada *
Europe
AWG 12
4 G 2.5
AWG 14
4 G 2.5
AWG 10
4 G 4
AWG 14
4 G 2.5
AWG 14
-
AWG 10
4 G 4
AWG 12
4 G 4
AWG 6
4 G 6
AWG 10
4 G 4
AWG 12
-
AWG 8
4 G 4
AWG 10
4 G 4
AWG 6
4 G 10
AWG 10
4 G 4
AWG 10
-
AWG 6
4 G 10
AWG 6
4 G 10
AWG 6
-