Process parameters
Overview
The "Process parameters" menu button contains the following selection options:
-
-
-
-
-
-
-
-
Process parame-
The following process parameters can be set and displayed for the start and end of weld-
ters for start of
ing:
welding / end of
welding
Starting current
for setting the starting current for MIG/MAG welding (e.g. aluminium welding start-up)
Unit
Setting range
Factory setting
Start arc length correction
for correcting the arc length at the start of welding
Unit
Setting range
Factory setting
-
0
+
Weld-Start / Weld-End
Gas-Setup
Process control
R/L-check / alignment
TIG/MMA/SMAW Setup
SynchroPulse
Components
Optimising a job
% (of welding current)
0 - 200
135
% (of welding voltage)
-10 - +10
0
shorter arc length
neutral arc length
longer arc length
97