Welding Parameters For Mig/Mag Standard Manual Welding; Explanation Of Footnotes - Fronius TPS 320i Operating Instructions Manual

Mig/mag power source
Table of Contents

Advertisement

Welding parame-
The following welding parameters for MIG/MAG standard manual welding can be set and
ters for MIG/MAG
displayed by selecting the "Welding" menu button:
standard manual
welding
Voltage
Unit
Setting range
Dynamic
For influencing the short-circuiting dynamic at the instant of droplet transfer
Setting range
Factory setting
0
10
Feeder command value
for setting a harder, more stable arc
Unit
Setting range
Explanation of
1)
footnotes
2)
3)
V
Depends on the welding process and welding program selected
0 - 10
0
Harder, more stable arc
Soft, low-spatter arc
m/min
0.5 -max.
Synergic parameter
When a synergic parameter is changed, the synergic function automatically chang-
es all other synergic parameters to match.
The real setting range depends on power source and wire feeder used and on the
welding programm.
The real setting range depends on the welding program.
The maximum value depends on the wire feeder used.
ipm.
2)
2)
19.69 -max.
71