Connecting MIG/
MAG welding
torches to the
wire-feed unit
54
*
7
6
4
Check that all cables, leads and hose-
1
packs are undamaged and correctly in-
sulated
Open the wire drive cover
2
Open the clamping lever on the wire
3
drive
Check that the welding torch is correc-
4
tly and completely tooled up. Insert it -
marking at the top first - into the wel-
ding torch connection on the wire-feed
unit
Close the clamping lever on the wire
5
drive
*
On water-cooled welding torches:
Connect the coolant flow hose to the
6
coolant flow connection (blue)
Connect the coolant return hose to the
7
coolant return connection (red)
Close the wire drive cover
8
Check that all connections are connec-
9
ted properly